Literature DB >> 10821097

First-generation aortic endografts: analysis of explanted Stentor devices from the EUROSTAR Registry.

R Guidoin1, Y Marois, Y Douville, M W King, M Castonguay, A Traoré, M Formichi, L E Staxrud, L Norgren, P Bergeron, J P Becquemin, J M Egana, P L Harris.   

Abstract

PURPOSE: To examine the structure and healing characteristics of chronically implanted Stentor endografts that were explanted due to migration, endoleak, thrombosis, or aneurysm expansion.
METHODS: The devices were harvested following reoperation (n = 5) or autopsy (n = 1) with implantation times ranging from 13 to 53 months. Structural modifications to the metal components were examined using radiography, endoscopy, and magnetic resonance imaging (MRI). Specimens taken from components of the modular stent-grafts were examined histologically and with scanning electron microscopy (SEM) to assess healing behavior. Physical and chemical stability of the nitinol wires and woven polyester graft material was evaluated using SEM and electron spectroscopy for chemical analysis.
RESULTS: Although the endografts were retrieved for a variety of reasons, they exhibited similar healing and structural modifications. The woven polyester sleeve showed evidence of yarn shifting and distortion, yarn damage, and filament breakage leading to the formation of openings in the fabric. The luminal surface endografts showed incomplete healing characterized by a poorly organized, nonadherent thrombotic matrix of variable thickness. Radiographic and endoscopic observations indicated that structural failure of the grafts, particularly in the main aortic component, was related to severe compaction and dislocation of the metallic frame due to suture breaks. Corrosion marks were observed on some nitinol wires in all devices. Chemical analysis and ion bombardment of the nitinol wires revealed that the surface concentrations of titanium and nickel were not homogenous. The first layer was composed of carbon or organic elements, followed by a stratum of highly oxidized titanium with a low nickel concentration; the titanium-nickel alloy lay beneath these layers.
CONCLUSIONS: Although the materials selected for construction of endovascular grafts appears judicious, the assembly of these biomaterials into various interrelated structures within the device requires further improvement.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10821097     DOI: 10.1177/152660280000700205

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  7 in total

Review 1.  Atrial septum defect closure device in a beating heart, from the perspective of a researcher in artificial organs.

Authors:  Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2012-06-23       Impact factor: 1.731

Review 2.  Research and development of metals for medical devices based on clinical needs.

Authors:  Takao Hanawa
Journal:  Sci Technol Adv Mater       Date:  2012-12-13       Impact factor: 8.090

3.  Regenerating titanium ventricular assist device surfaces after gold/palladium coating for scanning electron microscopy.

Authors:  Hardean E Achneck; Michael J Serpe; Ryan M Jamiolkowski; Leslie M Eibest; Stephen L Craig; Jeffrey H Lawson
Journal:  Microsc Res Tech       Date:  2010-01       Impact factor: 2.769

4.  Comparative study of the corrosion behavior of peripheral stents in an accelerated corrosion model: experimental in vitro study of 28 metallic vascular endoprostheses.

Authors:  Karolin J Paprottka; Philipp M Paprottka; Maximilian F Reiser; Tobias Waggershauser
Journal:  Diagn Interv Radiol       Date:  2015 Sep-Oct       Impact factor: 2.630

Review 5.  Postoperative Aortic Neck Dilation: Myth or Fact?

Authors:  A S Ribner; A K Tassiopoulos
Journal:  Int J Angiol       Date:  2018-05-23

6.  An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents.

Authors:  Jing Lin; Robert Guidoin; Jia Du; Lu Wang; Graeham Douglas; Danjie Zhu; Mark Nutley; Lygia Perron; Ze Zhang; Yvan Douville
Journal:  Materials (Basel)       Date:  2016-02-16       Impact factor: 3.623

Review 7.  Biocompatibility of titanium from the viewpoint of its surface.

Authors:  Takao Hanawa
Journal:  Sci Technol Adv Mater       Date:  2022-08-15       Impact factor: 7.821

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.