Literature DB >> 10820438

Near-terminus axonal structure and function following rat sciatic nerve regeneration through a collagen-GAG matrix in a ten-millimeter gap.

L J Chamberlain1, I V Yannas, H P Hsu, G R Strichartz, M Spector.   

Abstract

The objectives of this study were to evaluate the regenerated axon structure at near-terminal locations in the peroneal and tibial branches 1 year following implantation of several tubular devices in a 10-mm gap in the adult rat sciatic nerve and to determine the extent of recovery of selected sensory and motor functions. The devices were collagen and silicone tubes implanted alone or filled with a porous collagen-glycosaminoglycan matrix. Intact contralateral nerves and autografts were used as controls. Nerves were retrieved at 30 and 60 weeks postoperatively for histological evaluation of the number and diameter of regenerated axons proximal and distal to the gap and in the tibial and peroneal nerve branches, near the termination point. Several functional evaluation methods were employed: gait analysis, pinch test, muscle circumference, and response to electrical stimulation. A notable finding was that the matrix-filled collagen tube group had a significantly greater number of large-diameter myelinated axons (> or =6 microm in diameter) in the distal nerve branches than any other group, including the autograft group. These results were consistent with previously reported electrophysiological measurements that showed that the action potential amplitude for the A fibers in the matrix-filled collagen tube group was greater than for the autograft control group. Functional testing revealed the existence of both sensory and motor recovery following peripheral nerve regeneration through all devices; however, the tests employed in this study did not show differences among the groups with regeneration. Electrical stimulation in vivo showed that threshold parameters to elicit muscle twitch were the same for reinnervating and control nerves. The investigation is of importance in showing for the first time the superiority of a specific fully resorbable off-the-shelf device over an autograft for bridging gaps in peripheral nerve, with respect to the near-terminus axonal structure. Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10820438     DOI: 10.1002/(SICI)1097-4547(20000601)60:5<666::AID-JNR12>3.0.CO;2-0

Source DB:  PubMed          Journal:  J Neurosci Res        ISSN: 0360-4012            Impact factor:   4.164


  20 in total

1.  Cauda equina-derived extracellular matrix for fabrication of nanostructured hybrid scaffolds applied to neural tissue engineering.

Authors:  Xiaoxiao Wen; Yu Wang; Zhiyuan Guo; Haoye Meng; Jingxiang Huang; Li Zhang; Bin Zhao; Qing Zhao; Yudong Zheng; Jiang Peng
Journal:  Tissue Eng Part A       Date:  2014-12-16       Impact factor: 3.845

2.  Production of Highly Aligned Collagen Scaffolds by Freeze-drying of Self-assembled, Fibrillar Collagen Gels.

Authors:  Christopher J Lowe; Ian M Reucroft; Matthew C Grota; David I Shreiber
Journal:  ACS Biomater Sci Eng       Date:  2016-02-25

3.  Aligned collagen-GAG matrix as a 3D substrate for Schwann cell migration and dendrimer-based gene delivery.

Authors:  Antos Shakhbazau; Simon J Archibald; Dzmitry Shcharbin; Maria Bryszewska; Rajiv Midha
Journal:  J Mater Sci Mater Med       Date:  2014-05-07       Impact factor: 3.896

4.  Bone defect healing is induced by collagen sponge/polyglycolic acid.

Authors:  Shirin Toosi; Hojjat Naderi-Meshkin; Fatemeh Kalalinia; Hossein HosseinKhani; Asieh Heirani-Tabasi; Shahrzad Havakhah; Sirous Nekooei; Amir Hossein Jafarian; Fahimeh Rezaie; Mohammad Taghi Peivandi; Hooman Mesgarani; Javad Behravan
Journal:  J Mater Sci Mater Med       Date:  2019-03-06       Impact factor: 3.896

Review 5.  Surface biology of collagen scaffold explains blocking of wound contraction and regeneration of skin and peripheral nerves.

Authors:  I V Yannas; D Tzeranis; P T So
Journal:  Biomed Mater       Date:  2015-12-23       Impact factor: 3.715

6.  Bridging the Gap: Engineered Porcine-derived Urinary Bladder Matrix Conduits as a Novel Scaffold for Peripheral Nerve Regeneration.

Authors:  Lyly Nguyen; Ashkan Afshari; Nathaniel D Kelm; Alonda C Pollins; R Bruce Shack; Mark D Does; Wesley P Thayer
Journal:  Ann Plast Surg       Date:  2017-06       Impact factor: 1.539

7.  PRP-1 protective effect against central and peripheral neurodegeneration following n. ischiadicus transection.

Authors:  Armen A Galoyan; John S Sarkissian; Ruben M Sulkhanyan; Vergine A Chavushyan; Zubeida A Avetisyan; Zaruhi E Avakyan; Anoush J Gevorgyan; Davit O Abrahamyan; Yuri Kh Grigorian
Journal:  Neurochem Res       Date:  2005-04       Impact factor: 3.996

8.  Effects of collagen membranes enriched with in vitro-differentiated N1E-115 cells on rat sciatic nerve regeneration after end-to-end repair.

Authors:  Sandra Amado; Jorge M Rodrigues; Ana L Luís; Paulo A S Armada-da-Silva; Márcia Vieira; Andrea Gartner; Maria J Simões; António P Veloso; Michele Fornaro; Stefania Raimondo; Artur S P Varejão; Stefano Geuna; Ana C Maurício
Journal:  J Neuroeng Rehabil       Date:  2010-02-11       Impact factor: 4.262

9.  Effect of 3D-scaffold formation on differentiation and survival in human neural progenitor cells.

Authors:  Stefanie Ortinau; Jürgen Schmich; Stephan Block; Andrea Liedmann; Ludwig Jonas; Dieter G Weiss; Christiane A Helm; Arndt Rolfs; Moritz J Frech
Journal:  Biomed Eng Online       Date:  2010-11-11       Impact factor: 2.819

10.  Collagen tube conduits in peripheral nerve repair: a retrospective analysis.

Authors:  Kirk J Wangensteen; Loree K Kalliainen
Journal:  Hand (N Y)       Date:  2009-11-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.