Literature DB >> 10813865

A generalized k-sampling scheme for 3D fast spin echo.

E G Kholmovski1, D L Parker, A L Alexander.   

Abstract

The phase-encoding scheme can significantly affect the quality of fast spin-echo (FSE) images because the echo amplitude is modulated as a function of the echo position in k-space. The effects of the modulation in two-dimensional FSE imaging include ghosting and blurring artifacts and resolution loss in the phase-encoding (PE) direction. In 3D FSE imaging, the use of two PE directions presents the opportunity for improved PE schemes. A new scheme for assignment of echoes to views in 3D FSE, termed generalized, has been developed. This scheme distributes T(2) effects along both PE directions, allowing considerable flexibility in the selection of blurring artifact appearance. In a set of simulations, phantom experiments, and in vivo experiments, the performance of the generalized PE scheme for 3D FSE imaging was compared with the performance of existing PE schemes. The results demonstrate that the generalized PE scheme can be used to reduce blurring artifacts greatly relative to other PE techniques that are presently in use. This approach to PE can be used to manipulate the blurring artifact appearance and to optimize acquisition time.

Mesh:

Year:  2000        PMID: 10813865     DOI: 10.1002/(sici)1522-2586(200005)11:5<549::aid-jmri11>3.0.co;2-g

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  High-resolution 3D arteriography of chronic total peripheral occlusions using a T1-W turbo spin-echo sequence with inner-volume imaging.

Authors:  Smita Sampath; Amish N Raval; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

2.  Three-dimensional mapping of the creatine kinase enzyme reaction rate in muscles of the lower leg.

Authors:  Prodromos Parasoglou; Ding Xia; Gregory Chang; Antonio Convit; Ravinder R Regatte
Journal:  NMR Biomed       Date:  2013-02-25       Impact factor: 4.044

3.  Spectrally selective 3D TSE imaging of phosphocreatine in the human calf muscle at 3 T.

Authors:  Prodromos Parasoglou; Ding Xia; Ravinder R Regatte
Journal:  Magn Reson Med       Date:  2012-04-12       Impact factor: 4.668

4.  Three-dimensional saturation transfer ³¹P-MRI in muscles of the lower leg at 3.0 T.

Authors:  Prodromos Parasoglou; Ding Xia; Gregory Chang; Ravinder R Regatte
Journal:  Sci Rep       Date:  2014-06-09       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.