Literature DB >> 10810488

Mechanical properties of small fragment screws.

C A Collinge1, S Stern, S Cordes, E P Lautenschlager.   

Abstract

For many years, stainless steel small fragment screws have been produced by one manufacturer. Recently, other implant makers have begun offering similar stainless steel screws. In addition, screw geometry and material composition have been modified in an attempt to produce screws for a wide range of clinical situations. This study compared the mechanical properties of several commonly used small fragment screws. Seven sets of screws were tested mechanically, including three brands of geometrically identical standard stainless steel cortical screws and one brand each of cannulated stainless steel cortical screws, titanium cortical screws, stainless steel cancellous screws, and bioabsorbable polylactic acid screws. Screws from each group were tested for pullout strength, torque to failure, and three-point bending to failure. There were no differences in the mechanical properties of the identical 3.5-mm standard stainless steel cortical screws. No difference in pullout strength was found between the five sets of cortical screws. However, the cancellous screws had 4% to 24% less pullout strength. Torsion tests showed that cannulated stainless steel cortical, titanium cortical screws, stainless steel cancellous screws, and polylactic acid screws failed at significantly less torque than did standard stainless steel cortical screws. Standard stainless steel cortical screws had the highest mean yield point and maximal load at failure of all screws in three-point bending. Other metal screws had lower yield strength and maximal load at failure than did the standard stainless steel cortical screws, and polylactic acid screws had the least bending strength.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10810488     DOI: 10.1097/00003086-200004000-00034

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  3 in total

1.  Computational simulations of stress shielding and bone resorption around existing and computer-designed orthopaedic screws.

Authors:  A Gefen
Journal:  Med Biol Eng Comput       Date:  2002-05       Impact factor: 2.602

2.  Comparison of Partially Threaded and Fully Threaded 4mm Cancellous Screws in Fixation of Medial Malleolar Fractures.

Authors:  Sayyed-Hadi Sayyed-Hosseinian; Farshid Bagheri; Mohammad-Hosien Ebrahimzadeh; Ali Moradi; Sogol Golshan
Journal:  Arch Bone Jt Surg       Date:  2020-11

3.  Solid screw insertion for tension band plates: a surgical technique tip.

Authors:  Muayad Kadhim; Ahmed I Hammouda; John E Herzenberg
Journal:  J Child Orthop       Date:  2016-06-16       Impact factor: 1.548

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.