Literature DB >> 10807823

Quantitating physical activity in COPD using a triaxial accelerometer.

B G Steele1, L Holt, B Belza, S Ferris, S Lakshminaryan, D M Buchner.   

Abstract

STUDY
OBJECTIVE: To determine the reliability, validity, and stability of a triaxial accelerometer for walking and daily activity measurement in a COPD sample.
DESIGN: Cross-sectional, correlational, descriptive design.
SETTING: Outpatient pulmonary rehabilitation program in a university-affiliated Veterans Affairs medical center. PARTICIPANTS: Forty-seven outpatients (44 men and 3 women) with stable COPD (FEV(1), 37% predicted; SD, 16%) prior to entry into a pulmonary rehabilitation program. MEASUREMENTS AND
RESULTS: Test-retest reliability of a triaxial movement sensor (Tritrac R3D Research Ergometer; Professional Products; Madison, WI) was evaluated in 35 of the 47 subjects during three standardized 6-min walks (intraclass correlation coefficient [rICC] = 0.84). Pearson correlations evaluated accelerometer concurrent validity as a measure of walking (in vector magnitude units), compared to walking distance in all 47 subjects during three sequential 6-min walks (0. 84, 0.85, and 0.95, respectively; p < 0.001). The validity of the accelerometer as a measure of daily activity over 3 full days at home was evaluated in all subjects using Pearson correlations with other indicators of functional capacity. The accelerometer correlated with exercise capacity (maximal 6-min walk, r = 0.74; p < 0.001); level of obstructive disease (FEV(1) percent predicted, r = 0.62; p < 0.001); dyspnea (Functional Status and Dyspnea Questionnaire, dyspnea over the past 30 days, r = - 0.29; p < 0.05); and activity self-efficacy (Activity Self-Efficacy Questionnaire, r = 0.43; p < 0.01); but not with self-report of daily activity (Modified Activity Recall Questionnaire, r = 0.14; not significant). Stability of the accelerometer to measure 3 full days of activity at home was determined by an rICC of 0.69.
CONCLUSIONS: This study provides preliminary data suggesting that a triaxial movement sensor is a reliable, valid, and stable measure of walking and daily physical activity in COPD patients. It has the potential to provide more precise measurement of everyday physical functioning in this population than self-report measures currently in use, and measures an important dimension of functional status not previously well-described.

Entities:  

Mesh:

Year:  2000        PMID: 10807823     DOI: 10.1378/chest.117.5.1359

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  58 in total

Review 1.  Pulmonary rehabilitation.

Authors: 
Journal:  Thorax       Date:  2001-11       Impact factor: 9.139

Review 2.  Limits to the measurement of habitual physical activity by questionnaires.

Authors:  R J Shephard
Journal:  Br J Sports Med       Date:  2003-06       Impact factor: 13.800

3.  Physical activity patterns of patients with cardiopulmonary illnesses.

Authors:  Huong Q Nguyen; Bonnie G Steele; Cynthia M Dougherty; Robert L Burr
Journal:  Arch Phys Med Rehabil       Date:  2012-07-05       Impact factor: 3.966

4.  Clinically meaningful change estimates for the six-minute walk test and daily activity in individuals with chronic heart failure.

Authors:  Michael J Shoemaker; Amy B Curtis; Eric Vangsnes; Michael G Dickinson
Journal:  Cardiopulm Phys Ther J       Date:  2013-09

5.  Classification of basic daily movements using a triaxial accelerometer.

Authors:  M J Mathie; B G Celler; N H Lovell; A C F Coster
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

6.  Activity monitoring and energy expenditure in COPD patients: a validation study.

Authors:  Sanjay A Patel; Roberto P Benzo; William A Slivka; Frank C Sciurba
Journal:  COPD       Date:  2007-06       Impact factor: 2.409

7.  Accuracy of uniaxial accelerometer in chronic obstructive pulmonary disease.

Authors:  Marilyn L Moy; Eric Garshick; Kirby R Matthess; Robert Lew; John J Reilly
Journal:  J Rehabil Res Dev       Date:  2008

8.  Is laparoscopic colorectal surgery less invasive than classical open surgery? Quantitation of physical activity using an accelerometer to assess postoperative convalescence.

Authors:  Y Inoue; T Kimura; H Noro; M Yoshikawa; M Nomura; T Yumiba; E Taniguchi; S Ohashi; S Souda; H Matsuda
Journal:  Surg Endosc       Date:  2003-06-13       Impact factor: 4.584

9.  Laparoscopy-assisted distal gastrectomy versus open distal gastrectomy. A prospective randomized single-blind study.

Authors:  Shuji Takiguchi; Yoshiyuki Fujiwara; Makoto Yamasaki; Hiroshi Miyata; Kiyokazu Nakajima; Mitsugu Sekimoto; Masaki Mori; Yuichiro Doki
Journal:  World J Surg       Date:  2013-10       Impact factor: 3.352

10.  Social cognitive influences on physical activity behavior in middle-aged and older adults.

Authors:  Siobhan M White; Thomas R Wójcicki; Edward McAuley
Journal:  J Gerontol B Psychol Sci Soc Sci       Date:  2011-07-09       Impact factor: 4.077

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.