The protective effect of salbutamol inhaled using different devices on methacholine bronchoconstriction.

D Giannini1, A Di Franco, E Bacci, F L Dente, M Taccola, B Vagaggini, P Paggiaro.   

Abstract

STUDY
OBJECTIVE: To determine the protective effect of salbutamol, 100 microg, inhaled by different devices (pressurized metered-dose inhaler [pMDI; Ventolin; GlaxoWellcome; Greenford, UK], pMDI + spacer [Volumatic; GlaxoWellcome], or breath-activated pMDI [Autohaler; 3M Pharmaceuticals; St. Paul, MN]) on bronchoconstriction induced by methacholine.
DESIGN: Randomized, double-blind, cross-over, placebo-controlled study. PATIENTS: Eighteen subjects with stable, moderate asthma, asymptomatic, receiving regular treatment with salmeterol, 50 microg bid, and inhaled beclomethasone dipropionate, 250 microg bid, in the last 6 months, with high hyperreactivity to methacholine (baseline provocative dose of methacholine causing a 20% fall in FEV(1) [PD(20)] geometric mean [GM], 0.071 mg). Subjects were classified into two groups: subjects with incorrect (n = 5) pMDI inhalation technique, and subjects with correct (n = 13) inhalation technique. METHODS AND MEASUREMENTS: After cessation of therapy for 3 days, all subjects underwent four methacholine challenge tests, each test 1 week apart, each time 15 min after inhalation of salbutamol, 100 microg (via pMDI, pMDI + spacer, or Autohaler), or placebo. The protective effect on methacholine challenge test was evaluated as the change in the PD(20), and expressed in terms of doubling doses of methacholine in comparison with placebo treatment.
RESULTS: The PD(20) was significantly higher after salbutamol inhalation than after placebo inhalation, but no significant difference was observed among the three different inhalation techniques. Only when salbutamol was inhaled via pMDI + spacer, PD(20) was slightly but not significantly higher (pMDI GM, 0.454 mg; pMDI + spacer GM, 0.559 mg; and Autohaler GM, 0.372 mg; not significant [NS]) than other inhalation techniques. Similar results (mean +/-SEM) were obtained with doubling doses of methacholine (pMDI, 2 +/- 0.47; pMDI + spacer, 3 +/- 0.35; and Autohaler, 2.4 +/- 0.40; NS). No significant difference was found among techniques when subjects with correct or incorrect inhalation technique were separately considered.
CONCLUSIONS: Our data show that the protective effect of salbutamol, 100 microg, on methacholine-induced bronchoconstriction is not affected by the different inhalation techniques, although inhalation via pMDI + spacer tends to improve the bronchoprotective ability of salbutamol. These data confirm the clinical efficacy of salbutamol, whatever the device, and the patient's inhalation technique.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10807817     DOI: 10.1378/chest.117.5.1319

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  9 in total

Review 1.  Regular treatment with long acting beta agonists versus daily regular treatment with short acting beta agonists in adults and children with stable asthma.

Authors:  E H Walters; J A Walters; P W Gibson
Journal:  Cochrane Database Syst Rev       Date:  2002

2.  Assessment of different methods of inhalation from salbutamol metered dose inhalers by urinary drug excretion and methacholine challenge.

Authors:  Heather S Tomlinson; Sarah A Corlett; Martin B Allen; Henry Chrystyn
Journal:  Br J Clin Pharmacol       Date:  2005-12       Impact factor: 4.335

3.  Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering beta (2 )agonists bronchodilators in asthma.

Authors:  F S Ram; J Wright; D Brocklebank; J E White
Journal:  BMJ       Date:  2001-10-20

Review 4.  Addition of long-acting beta2-agonists to inhaled steroids versus higher dose inhaled steroids in adults and children with persistent asthma.

Authors:  Francine M Ducharme; Muireann Ni Chroinin; Ilana Greenstone; Toby J Lasserson
Journal:  Cochrane Database Syst Rev       Date:  2010-04-14

Review 5.  Addition of long-acting beta2-agonists to inhaled corticosteroids versus same dose inhaled corticosteroids for chronic asthma in adults and children.

Authors:  Francine M Ducharme; Muireann Ni Chroinin; Ilana Greenstone; Toby J Lasserson
Journal:  Cochrane Database Syst Rev       Date:  2010-05-12

6.  Salbutamol pMDI gives less protection to methacholine induced airway obstruction than salbutamol via spacer or DPI.

Authors:  Mariëlle E A C Broeders; Johan Molema; Wim C J Hop; Hans Th M Folgering
Journal:  Eur J Clin Pharmacol       Date:  2004-12-30       Impact factor: 2.953

7.  Comparison of bronchoprotective and bronchodilator effects of a single dose of formoterol delivered by hydrofluoroalkane and chlorofluorocarbon aerosols and dry powder in a double blind, placebo-controlled, crossover study.

Authors:  C M Houghton; S J Langley; S D Singh; J Holden; A P Monici Preti; D Acerbi; G Poli; A Woodcock
Journal:  Br J Clin Pharmacol       Date:  2004-10       Impact factor: 4.335

Review 8.  Addition of inhaled long-acting beta2-agonists to inhaled steroids as first line therapy for persistent asthma in steroid-naive adults and children.

Authors:  Muireann Ni Chroinin; Ilana Greenstone; Toby J Lasserson; Francine M Ducharme
Journal:  Cochrane Database Syst Rev       Date:  2009-10-07

9.  Effect of Study Design on Sample Size in Studies Intended to Evaluate Bioequivalence of Inhaled Short-Acting β-Agonist Formulations.

Authors:  Yaohui Zeng; Sachinkumar Singh; Kai Wang; Richard C Ahrens
Journal:  J Clin Pharmacol       Date:  2017-12-27       Impact factor: 3.126

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.