Literature DB >> 10807816

Salmeterol administration by metered-dose inhaler alone vs metered-dose inhaler plus valved holding chamber.

K Demirkan1, E Tolley, T Mastin, J Soberman, J Burbeck, T Self.   

Abstract

STUDY
OBJECTIVE: To determine whether a spacer device designed as a valved holding chamber with a flow signal increases the efficacy of the long-acting beta(2)-agonist, salmeterol, in patients who use incorrect technique with metered-dose inhaler (MDI) alone.
DESIGN: Double-blind, randomized, placebo-controlled study.
SETTING: University hospital outpatient rooms. PATIENTS: Twenty adult outpatients with stable persistent asthma, receiving a daily anti-inflammatory drug.
INTERVENTIONS: Patients were randomized to either salmeterol MDI (incorrect use: 1 s after actuating MDI, inhale rapidly) and placebo plus spacer (correct use: inhale slowly as MDI is actuated, continue to inhale slowly and deeply) or placebo MDI (incorrect use) and salmeterol plus spacer (correct use). The following week, patients received the opposite treatment. The dose was two puffs from each device on each treatment day; each puff was separated by 1 min. MEASUREMENTS AND
RESULTS: After baseline peak expiratory flow (PEF), salmeterol was administered and serial PEF determined (0.5, 1, 2, 3, 4, 6, 8, 10, and 12 h). Administration of salmeterol MDI plus spacer resulted in significantly greater increases in PEF from baseline vs MDI at 4 h (44 L/min vs 10 L/min; p < 0.01) and 6 h (49 L/min vs 24 L/min; p < 0.05). Both methods of administration were equally well tolerated.
CONCLUSION: We conclude that patients who have poor timing and rapid inhalation with salmeterol MDI alone will have greater increases in PEF at 4 h and 6 h and no additional side effects if the dose is administered with a valved holding chamber that is used correctly. Further study is needed regarding other errors in MDI technique with salmeterol.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10807816     DOI: 10.1378/chest.117.5.1314

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  6 in total

1.  Hold it! Correct use of inhalers in children with asthma.

Authors:  M L Abrolat; L P Nguyen; L F Saca
Journal:  West J Med       Date:  2001-11

Review 2.  Epidemiology and management of common pulmonary diseases in older persons.

Authors:  Kathleen M Akgün; Kristina Crothers; Margaret Pisani
Journal:  J Gerontol A Biol Sci Med Sci       Date:  2012-02-15       Impact factor: 6.053

Review 3.  Regular treatment with salmeterol for chronic asthma: serious adverse events.

Authors:  Christopher J Cates; Matthew J Cates
Journal:  Cochrane Database Syst Rev       Date:  2008-07-16

4.  Potential of a cyclone prototype spacer to improve in vitro dry powder delivery.

Authors:  Irene Parisini; Sean J Cheng; Digby D Symons; Darragh Murnane
Journal:  Pharm Res       Date:  2014-05       Impact factor: 4.200

Review 5.  A Rationale for Going Back to the Future: Use of Disposable Spacers for Pressurised Metered Dose Inhalers.

Authors:  Mark Sanders; Ronald Bruin
Journal:  Pulm Med       Date:  2015-09-27

Review 6.  A review of the in vitro and in vivo valved holding chamber (VHC) literature with a focus on the AeroChamber Plus Flow-Vu Anti-static VHC.

Authors:  Sanjeeva Dissanayake; Jason Suggett
Journal:  Ther Adv Respir Dis       Date:  2018 Jan-Dec       Impact factor: 4.031

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.