Literature DB >> 1080646

[The sources of ophthalmodynamography. Determination of tissue volumes of human lids and orbital contents (author's transl)].

H Derka.   

Abstract

The volumetric determination of all those tissues relevant for Opthalmodynamography (ODG) showed the lids to contribute about a quarter to the total volume; another quarter each was due to the optic bulb including optic fascicel, external bulbar musculature and orbital fat. Bulb and fascicel show no pulsations that could be detected oscillographically, fat tissue is poorly vascularized and therefore is of minor importance in respect to the origin of pulsation. The main causes of ODG-oscillations therefore are external eye muscels and eye lids, each contributing a minimum of one third to the heights of the pulse. Assuming all tissues of possible importance for the origin of ODG to be equally well vascularized the part of ODG pulse height due to influence of eye lids is minimally 25% or 32% in the average.

Entities:  

Mesh:

Year:  1975        PMID: 1080646     DOI: 10.1007/bf00414801

Source DB:  PubMed          Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol        ISSN: 0065-6100


  12 in total

1.  [The importance of the eyelids for ophthalmodynamographic recordings-- an oscillographic study before and after total plastic reconstruction of the eyelids (authors transl)].

Authors:  H Derka
Journal:  Wien Klin Wochenschr       Date:  1975-09-19       Impact factor: 1.704

2.  [Ophthalmo-dynamography as a method of evaluating brain circulation].

Authors:  H HAGER
Journal:  Klin Monbl Augenheilkd       Date:  1963-06       Impact factor: 0.700

3.  The determination of orbital volume.

Authors:  J C ALEXANDER; J E ANDERSON; J C HILL
Journal:  Trans Can Opthalmolog Soc       Date:  1961

4.  [Relationship between orbital and cerebral pulse-wave amplitude. Comparative ophthalmodynamographic and rheoencephalographic studies].

Authors:  H Derka; F L Jenkner
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1973

5.  Comparison of direct and indirect determinations of rabbit orbital volume.

Authors:  T K Prechter; B G Sarnat
Journal:  Acta Morphol Neerl Scand       Date:  1973-06

6.  Orbital growth after evisceration or enucleation without and with implants.

Authors:  B G Sarnat; P D Shanedling
Journal:  Acta Anat (Basel)       Date:  1972

7.  [Influence of the arteria carotis externa on the ophthalmodynamographic curve].

Authors:  H Derka
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1969-09-22

8.  [The dynamogram of the "empty" orbit: dynamographic investigations in patients with unilateral postoperative anophthalmus].

Authors:  H Bettelheim
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1969

9.  [The influence of the external carotid artery vascular area on the ophthalmic arterial blood pressure and the bulbo-orbital oscillogram].

Authors:  H Bettelheim
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1966-10-11

10.  The imprint method to determine orbital volume in the rabbit.

Authors:  B G Sarnat
Journal:  Ophthalmologica       Date:  1970       Impact factor: 3.250

View more
  1 in total

1.  Ophthalmodynamography and ophthalmodynamometry in neurological practice.

Authors:  F Strik
Journal:  Doc Ophthalmol       Date:  1980-05-30       Impact factor: 2.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.