Literature DB >> 10805939

Optimal parameters for laser tissue soldering: II. Premixed versus separate dye-solder techniques.

K M McNally1, B S Sorg, E K Chan, A J Welch, J M Dawes, E R Owen.   

Abstract

BACKGROUND AND
OBJECTIVE: Laser tissue soldering by using an indocyanine green (ICG)-doped protein solder applied topically to the tissue surface and denatured with a diode laser was investigated in Part I of this study. The depth of light absorption was predominantly determined by the concentration of the ICG dye added to the solder. This study builds on that work with an in vitro investigation of the effects of limiting the zone of heat generation to the solder-tissue interface to determine whether more stable solder-tissue fusion can be achieved. STUDY DESIGN/
MATERIALS AND METHODS: An alternative laser tissue soldering technique was investigated, which increased light absorption at the vital solder-tissue interface. A thin layer of ICG dye was smeared over the surface to be treated, the protein solder was then placed directly on top of the dye, and the solder was denatured with an 808-nm diode laser. Because laser light at approximately 800 nm is absorbed primarily by the ICG dye, this thin layer of ICG solution restricted the heat source to the space between the solder and the tissue surfaces. A tensile strength analysis was conducted to compare the separate dye-solder technique with conventional techniques of laser tissue soldering for which a premixed dye-solder is applied directly to the tissue surface. The effect of hydration on bond stability of repairs formed by using both techniques was also investigated using tensile strength and scanning electron microscopy analysis.
RESULTS: Equivalent results in terms of tensile strength were obtained for the premixed dye-solder technique using protein solders containing 0.25 mg/ml ICG (liquid solder, 220 +/- 35 N/cm(2); solid solder, 602 +/- 32 N/cm(2)) and for the separate dye-solder technique (liquid solder, 228 +/- 41 N/cm(2); solid solder, 578 +/- 29 N/cm(2)). The tensile strength of native bovine thoracic aorta was 596 +/- 31 N/cm(2). Repairs created by using the separate dye-solder technique were more stable during hydration than their premixed dye-solder counterparts. The conventional premixed dye-solder was simpler and approximately twice as fast to apply. The separate dye-solder technique, however, increased the shelf-life of the solder, because the dye was mixed at the time of the experiment, thus conserving its spectral absorbency properties.
CONCLUSION: Two laser-assisted tissue soldering techniques have been evaluated for repairing aorta incisions in vitro. The advantages and disadvantages of each of these techniques are discussed. Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10805939     DOI: 10.1002/(sici)1096-9101(2000)26:4<346::aid-lsm2>3.0.co;2-v

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  6 in total

1.  An in-vitro investigation of skin tissue soldering using gold nanoshells and diode laser.

Authors:  Mohammad S Nourbakhsh; Mohammad E Khosroshahi
Journal:  Lasers Med Sci       Date:  2010-07-10       Impact factor: 3.161

2.  Closure of skin incisions by 980-nm diode laser welding.

Authors:  Murat Gulsoy; Zeynep Dereli; Hasim O Tabakoglu; Ozguncem Bozkulak
Journal:  Lasers Med Sci       Date:  2006-03-17       Impact factor: 3.161

3.  Characterization of skin tissue soldering using diode laser and indocyanine green: in vitro studies.

Authors:  M E Khosroshahi; M S Nourbakhsh; S Saremi; F Tabatabaee
Journal:  Lasers Med Sci       Date:  2009-05-16       Impact factor: 3.161

4.  Dynamic characterization of indocyanine green-assisted dental caries ablation with continuous diode laser using thermal imaging and fluorescence spectroscopy.

Authors:  Mohammad E Khosroshahi; Faezeh D Farahani; Lida Ghazanfari; Vaughan Woll-Morison
Journal:  Lasers Med Sci       Date:  2020-08-08       Impact factor: 3.161

5.  Optimization of suture-free laser-assisted vessel repair by solder-doped electrospun poly(ε-caprolactone) scaffold.

Authors:  Dara R Pabittei; Michal Heger; Johan F Beek; Sjoerd van Tuijl; Marc Simonet; Allard C van der Wal; Bas A de Mol; Ron Balm
Journal:  Ann Biomed Eng       Date:  2010-09-11       Impact factor: 3.934

Review 6.  Cutaneous wound closure materials: an overview and update.

Authors:  Luluah Al-Mubarak; Mohammed Al-Haddab
Journal:  J Cutan Aesthet Surg       Date:  2013-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.