Literature DB >> 10802852

Quantification of video-taped images in microcirculation research using inexpensive imaging software (Adobe Photoshop).

J Brunner1, F Krummenauer, H A Lehr.   

Abstract

BACKGROUND: Study end-points in microcirculation research are usually video-taped images rather than numeric computer print-outs. Analysis of these video-taped images for the quantification of microcirculatory parameters usually requires computer-based image analysis systems. Most software programs for image analysis are custom-made, expensive, and limited in their applicability to selected parameters and study end-points. METHODS AND RESULT: We demonstrate herein that an inexpensive, commercially available computer software (Adobe Photoshop), run on a Macintosh G3 computer with inbuilt graphic capture board provides versatile, easy to use tools for the quantification of digitized video images. Using images obtained by intravital fluorescence microscopy from the pre- and postischemic muscle microcirculation in the skinfold chamber model in hamsters, Photoshop allows simple and rapid quantification (i) of microvessel diameters, (ii) of the functional capillary density and (iii) of postischemic leakage of FITC-labeled high molecular weight dextran from postcapillary venules. We present evidence of the technical accuracy of the software tools and of a high degree of interobserver reliability.
CONCLUSION: Inexpensive commercially available imaging programs (i.e., Adobe Photoshop) provide versatile tools for image analysis with a wide range of potential applications in microcirculation research.

Entities:  

Mesh:

Year:  2000        PMID: 10802852     DOI: 10.1038/sj.mn.7300094

Source DB:  PubMed          Journal:  Microcirculation        ISSN: 1073-9688            Impact factor:   2.628


  4 in total

1.  Histomorphometry of the ligaments using a generic-purpose image processing software, a new strategy for semi-automatized measurements.

Authors:  Rafael Ballesteros; Nuria Bonsfills; Marta Chacón; Javier García-Lázaro; Enrique Gómez-Barrena
Journal:  J Digit Imaging       Date:  2012-08       Impact factor: 4.056

2.  Microvasculatory reaction of skeletal muscle to Ti-15Mo in comparison to well-established titanium alloys.

Authors:  Peter H Pennekamp; Markus A Wimmer; Lukas Eschbach; Björn Burian; Peter Koch; Clayton N Kraft
Journal:  J Mater Sci Mater Med       Date:  2007-06-09       Impact factor: 3.896

3.  Agreement between clinical estimation and a new quantitative analysis by Photoshop software in fundus and angiographic image variables.

Authors:  Alireza Ramezani; Hamid Ahmadieh; Mohsen Azarmina; Masoud Soheilian; Mohammad H Dehghan; Mohammad R Mohebbi
Journal:  Int Ophthalmol       Date:  2008-09-19       Impact factor: 2.031

4.  Molecular and cellular basis of microvascular perfusion deficits induced by Clostridium perfringens and Clostridium septicum.

Authors:  Michael J Hickey; Rain Y Q Kwan; Milena M Awad; Catherine L Kennedy; Lauren F Young; Pam Hall; Leanne M Cordner; Dena Lyras; John J Emmins; Julian I Rood
Journal:  PLoS Pathog       Date:  2008-04-11       Impact factor: 6.823

  4 in total