Literature DB >> 10802007

Improved reliability for echocardiographic measurement of left ventricular volume using harmonic power imaging mode combined with contrast agent.

S Lafitte1, P Dos Santos, A Kerouani, T Robhan, R Roudaut.   

Abstract

Harmonic power imaging (HPI) is a new echocardiographic modality that enhances the detection of contrast agents in the left ventricle. The endocardium can be delineated by conventional echocardiography using ultrasound contrast agents, although the images tend to be faint. The present study was designed to assess left ventricular volume using HPI after intravenous injection of the contrast agent Levovist (Schering SA, Berlin, Germany) in 25 unselected patients. End-diastolic volume, end-systolic volume, and ejection fraction were determined for each patient with angiography and with 4 different ultrasound modalities: (1) conventional mode without contrast, (2) contrast conventional mode, (3) contrast harmonic intermittent imaging mode, and (4) contrast triggered HPI. The use of HPI improved correlations between the echographic and angiographic measurements for all parameters as well as precision and bias determined by Bland and Altman analysis. The relative errors for interobserver variability were also lower with HPI. This study demonstrates that echocardiographic determination of left ventricular volumes and ejection fraction is more accurate and reproducible using HPI combined with Levovist.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10802007     DOI: 10.1016/s0002-9149(00)00734-7

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

1.  Impact of Contrast Echocardiography on Assessment of Ventricular Function and Clinical Diagnosis in Routine Clinical Echocardiography: Korean Multicenter Study.

Authors:  Doo-Youp Kim; Jung-Hyun Choi; Geu-Ru Hong; Se-Joong Rim; Jang-Young Kim; Sang-Chol Lee; Il-Suk Sohn; Wook-Jin Chung; Hye-Sun Seo; Se-Jung Yoon; Kyoung-Im Cho; Si-Wan Choi; Kyung-Jin Lee
Journal:  J Cardiovasc Ultrasound       Date:  2017-03-27

2.  Contrast-enhanced versus non-enhanced three-dimensional echocardiography of left ventricular volumes.

Authors:  J A van der Heide; H F J Mannaerts; L Yang; G T Sieswerda; C A Visser; O Kamp
Journal:  Neth Heart J       Date:  2008-02       Impact factor: 2.380

3.  Impact of image quality on reliability of the measurements of left ventricular systolic function and global longitudinal strain in 2D echocardiography.

Authors:  Yasufumi Nagata; Yuichiro Kado; Takeshi Onoue; Kyoko Otani; Akemi Nakazono; Yutaka Otsuji; Masaaki Takeuchi
Journal:  Echo Res Pract       Date:  2018-02-05