Literature DB >> 1080159

Simple screening tests for the diagnosis of isolated clotting factor defects. With special reference to 'contact factor' defects.

G I Ingram, S F Knights, C L Arocha-Piñango, J P Shepperd, J L Pérez-Requejo, D K Mills.   

Abstract

Reagents may be prepared from normal plasma and used with the prothrombin time and partial thromboplastin time tests to distinguish isolated defects of factors I, II, VII, VIII, IX, X, XI, or XII.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1080159      PMCID: PMC475764          DOI: 10.1136/jcp.28.7.524

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  8 in total

1.  A one-stage factor VIII (antihaemophilic globulin) assay and its use on venous and capillary plasma.

Authors:  R M HARDISTY; J C MACPHERSON
Journal:  Thromb Diath Haemorrh       Date:  1962-05-15

2.  Initiation of blood coagulation by glass and related surfaces.

Authors:  J MARGOLIS
Journal:  J Physiol       Date:  1957-06-18       Impact factor: 5.182

3.  Preparation of 'contact product' as a reagent for coagulation tests.

Authors:  J L Pérez-Requejo; G I Ingram
Journal:  J Clin Pathol       Date:  1975-07       Impact factor: 3.411

4.  A new method for the assay of factor XI in plasma and the preparation and use of a new artificial substrate.

Authors:  R E Blewitt
Journal:  J Clin Pathol       Date:  1975-04       Impact factor: 3.411

5.  The recognition of Hageman deficiency in blood donors.

Authors:  W L MARSH; W J JENKINS
Journal:  J Clin Pathol       Date:  1961-09       Impact factor: 3.411

6.  Preparation and use of a new artificial system for factor XI assay.

Authors:  J C Giddings
Journal:  Med Lab Technol       Date:  1971-07

7.  PARTIAL THROMBOPLASTIN TIME TEST WITH KAOLIN. NORMAL RANGE AND MODIFICATIONS FOR THE DIAGNOSIS OF HAEMOPHILIA AND CHRISTMAS DISEASE.

Authors:  M O MATCHETT; G I INGRAM
Journal:  J Clin Pathol       Date:  1965-07       Impact factor: 3.411

8.  Partial thromboplastin time test with kaolin: diagnosis of haemophilia and Christmas disease without natural reference plasmas.

Authors:  S F Knights; G I Ingram
Journal:  J Clin Pathol       Date:  1967-07       Impact factor: 3.411

  8 in total
  2 in total

1.  Preparation of 'contact product' as a reagent for coagulation tests.

Authors:  J L Pérez-Requejo; G I Ingram
Journal:  J Clin Pathol       Date:  1975-07       Impact factor: 3.411

2.  An approach to the evaluation of hemostasis.

Authors:  S B Hunter; F S Royal; L D Green
Journal:  J Natl Med Assoc       Date:  1977-09       Impact factor: 1.798

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.