Dosimetry of a W-188/Re-188 beta line source for endovascular brachytherapy.

U O Häfeli1, W K Roberts, D S Meier, J P Ciezki, G J Pauer, E J Lee, M S Weinhous.   

Abstract

PURPOSE: The objective was to determine the dosimetry of a potential endovascular brachytherapy source consisting of a coiled tungsten wire mounted on the distal end of a drive wire and neutron-activated to contain the parent-daughter nuclides tungsten-188 (188W) and rhenium-188 (188Re).
METHODS: A coiled tungsten wire 40 mm in length was neutron-activated by double-neutron capture for 78 hours at 1.9 x 10(15) h/cm2/s to contain 925 MBq (25 mCi) of 188W/188Re in equilibrium. The dose-fall off from this source was determined using three independent methods: (a) Thermoluminescence dosimetry with small LiF-100 rods, (b) Gafchromic film dosimetry, and (c) Bang gel dosimetry. In addition, a Monte Carlo simulation was performed to compute the beta-dose.
RESULTS: Each of the three measurement methods recorded similar values for the dose fall-off within the distances useful for endovascular brachytherapy. The Monte Carlo calculations closely approximated the measured results in the treatment range between 1 and 3 mm and may thus be useful for evaluating changing geometries in the development of catheters and source setups. A 2 min restenosis treatment delivering 20 Gy at a radius of 2 mm would require a source of 1384.8 MBq/cm (37.4 mCi/cm).
CONCLUSIONS: The dose distribution from a 188W/188Re source is similar to that of a 90Y-source. An added advantage of the 188W/188Re source is that it can be used for at least two months and still provides fast treatment times because of the parent isotope's half-life of 69 days. The additional gamma emission from the source is too small to impose a serious radiological hazard. The high atomic number and density of the source material allows direct fluoroscopic imaging without additional markers.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10798688     DOI: 10.1118/1.598928

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Using matrix summation method for three dimensional dose calculation in brachytherapy.

Authors:  Mahmoud Zibandeh-Gorji; Ali Asghar Mowlavi; Saeed Mohammadi
Journal:  Rep Pract Oncol Radiother       Date:  2012-02-09

Review 2.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

3.  Pharmacokinetics of radioimmunotherapeutic agent of direct labeling mAb 188Re-HAb18.

Authors:  Chao Lou; Zhi-Nan Chen; Hui-Jie Bian; Jie Li; Shou-Bo Zhou
Journal:  World J Gastroenterol       Date:  2002-02       Impact factor: 5.742

Review 4.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.