Literature DB >> 10795984

Polyvinyl alcohol-Fricke hydrogel and cryogel: two new gel dosimetry systems with low Fe3+ diffusion.

K C Chu1, K J Jordan, J J Battista, J Van Dyk, B K Rutt.   

Abstract

Two new Fricke dosimeter gel systems with low diffusion rates have been developed for 3D radiation dosimetry purposes. Both systems consist of a solution of 20% (by weight) polyvinyl alcohol (PVA) in a 50 mM H2SO4 solution with 0.4 mM ferrous ammonium sulphate and xylenol orange (FX). The difference in the two gels is the way that the gelation process was initiated: either by bringing the temperature to (a) +5 degrees C or (b) -20 degrees C before returning them to room temperature. These gels are termed 'hydrogel' and 'cryogel', respectively. The hydrogel is optically transparent, and can be used with either optical or MRI detection methods for dosimetric imaging. The cryogel is rubbery in texture but opaque, so its internal Fe3+ concentration can only be measured with MRI. The hydrogel's optical attenuation coefficient is linear (r2 = 0.99) with dose from 0 to 20 Gy with a sensitivity of 0.106 cm(-1) Gy(-1) (at 543 nm). In terms of MR relaxation rate, the dose response for both the hydrogel and cryogel was linear (r2 = 0.99) with a sensitivity of 0.020 s(-1) Gy(-1) (at 1.5 T). The Fe3+ diffusion coefficient (at 20 degrees C) was measured to be 0.14 mm2 h(-1), which is significantly lower than similar preparations reported for porcine gelatin or agarose. The PVA-FX gels can be stored for long periods of time before exposure to radiation, since the auto-oxidation rate was 10 times less than that of gelatin-Fricke recipes. The new gels developed in this work are a significant improvement on previous Fricke gel systems.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10795984     DOI: 10.1088/0031-9155/45/4/311

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Characterization of a new radiochromic three-dimensional dosimeter.

Authors:  P Y Guo; J A Adamovics; M Oldham
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

2.  A practical three-dimensional dosimetry system for radiation therapy.

Authors:  Pengyi Guo; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

3.  Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation.

Authors:  H S Sakhalkar; M Oldham
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

4.  Facile Fabrication of Transparent and Opaque Albumin Methacryloyl Gels with Highly Improved Mechanical Properties and Controlled Pore Structures.

Authors:  Mengdie Xu; Nabila Mehwish; Bae Hoon Lee
Journal:  Gels       Date:  2022-06-10

5.  Optical-CT 3D Dosimetry Using Fresnel Lenses with Minimal Refractive-Index Matching Fluid.

Authors:  Steven Bache; Javian Malcolm; John Adamovics; Mark Oldham
Journal:  PLoS One       Date:  2016-03-28       Impact factor: 3.240

6.  Radiological properties of nanocomposite Fricke gel dosimeters for heavy ion beams.

Authors:  Takuya Maeyama; Nobuhisa Fukunishi; Kenichi L Ishikawa; Kazuaki Fukasaku; Shigekazu Fukuda
Journal:  J Radiat Res       Date:  2016-03-10       Impact factor: 2.724

7.  Determine the Dose Distribution Using Ultrasound Parameters in MAGIC-f Polymer Gels.

Authors:  Hossein Masoumi; Manijhe Mokhtari-Dizaji; Azim Arbabi; Mohsen Bakhshandeh
Journal:  Dose Response       Date:  2016-02-11       Impact factor: 2.658

Review 8.  Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications.

Authors:  Yoichi Watanabe; Leighton Warmington; N Gopishankar
Journal:  World J Radiol       Date:  2017-03-28

9.  Measurement of skin surface dose distributions in radiation therapy using poly(vinyl alcohol) cryogel dosimeters.

Authors:  Molham M Eyadeh; Marcin Wierzbicki; Kevin R Diamond
Journal:  J Appl Clin Med Phys       Date:  2017-04-24       Impact factor: 2.102

10.  MAGIC polymer gel for dosimetric verification in boron neutron capture therapy.

Authors:  Jouni Uusi-Simola; Sami Heikkinen; Petri Kotiluoto; Tom Serén; Tiina Seppälä; Iiro Auterinen; Sauli Savolainen
Journal:  J Appl Clin Med Phys       Date:  2007-04-30       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.