Literature DB >> 10795463

Tissue reactions, fluids, and bacterial infiltration in implants retrieved at autopsy: a case report.

G Orsini1, S Fanali, A Scarano, G Petrone, S di Silvestro, A Piattelli.   

Abstract

A 72-year-old patient underwent the placement of 2 screw-type implants. After 5 months the patient died of a massive stroke, and a block section of the portion of the mandible containing the implants was done. The specimen was treated to obtain thin ground sections. A 1- to 5-micron gap was present between the implant and the healing cover screw, and this space was filled by bacteria and calculus; bacteria were also present in the most apical portion of the hollow part of the implant. An inflammatory infiltrate was present in the connective peri-implant tissues. The spaces between all implant components (implant, abutment, and healing screw) can act as conduits and reservoirs for bacteria, which could cause inflammation of the peri-implant soft tissues. In conclusion, the histologic data from this autopsy case may help to confirm the penetration by fluids and bacteria into the internal portion of the implants, obtained from previous in vitro and in vivo studies.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10795463

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  5 in total

1.  Marginal bone response of implants with platform switching and non-platform switching abutments in posterior healed sites: a 1-year prospective study.

Authors:  Yun-Chi Wang; Joseph Y K Kan; Kitichai Rungcharassaeng; Phillip Roe; Jaime L Lozada
Journal:  Clin Oral Implants Res       Date:  2014-01-03       Impact factor: 5.977

2.  Leakage of Microbial Endotoxin through the Implant-Abutment Interface in Oral Implants: An In Vitro Study.

Authors:  Rhoodie Garrana; Govindrau Mohangi; Paulo Malo; Miguel Nobre
Journal:  Biomed Res Int       Date:  2016-12-29       Impact factor: 3.411

3.  In Vitro Bacterial Leakage at the Implant-Abutment Connection of Two Dental Implant Systems with Internal Connection.

Authors:  Azadeh Khajavi; Shabnam Mohseni; Amir Peymani; Mehrak Amjadi
Journal:  Front Dent       Date:  2020-12-08

4.  Thermal conduction of titanium implants under CO2 laser irradiation in vitro.

Authors:  J Thomas Lambrecht; Tino Nyffeler; Manuela Linder
Journal:  Ann Maxillofac Surg       Date:  2012-01

5.  In vitro evaluation of leakage at implant-abutment connection of three implant systems having the same prosthetic interface using rhodamine B.

Authors:  Antoine Berberi; Georges Tehini; Khaldoun Rifai; Farah Bou Nasser Eddine; Nabil El Zein; Bassam Badran; Haidar Akl
Journal:  Int J Dent       Date:  2014-05-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.