Literature DB >> 10794228

Influence of mechanical behavior on the wear of 4 clinically relevant polymeric biomaterials in a hip simulator.

A A Edidin1, S M Kurtz.   

Abstract

The elastic and large-deformation mechanical behavior of 4 materials with known clinical performance was examined and correlated with the wear behavior in a hip simulator. Acetabular liners of a commercially available design were machined from ultra-high molecular weight polyethylene (UHMWPE), high-density polyethylene (HDPE), polytetrafluoroethylene (PTFE), and polyacetal and wear tested in a multidirectional hip joint simulator. Elastic and large-deformation mechanical behavior was directly measured from the wear-tested liners using the small punch test. The finite element method was used to compute elastic modulus from the measured small punch test initial stiffness, and the contact stress for the liners was calculated using the theory of elasticity solution. Positive, statistically significant correlations were observed between the hip simulator wear rate and the initial peak load, ultimate load, and work to failure from the small punch test. Negative correlations were observed between the wear rate and the elastic modulus and contact stress. The results of this study support the hypothesis that the large-deformation mechanical behavior of a polymer plays a greater role in the wear mechanisms prevalent in total hip replacements than the elastic behavior.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10794228     DOI: 10.1016/s0883-5403(00)90647-8

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

1.  Microencapsulation of 2-octylcyanoacrylate tissue adhesive for self-healing acrylic bone cement.

Authors:  Alice B W Brochu; William J Chyan; William M Reichert
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-07-18       Impact factor: 3.368

Review 2.  Self-healing biomaterials.

Authors:  Alice B W Brochu; Stephen L Craig; William M Reichert
Journal:  J Biomed Mater Res A       Date:  2010-12-09       Impact factor: 4.396

3.  Mechanical and cytotoxicity testing of acrylic bone cement embedded with microencapsulated 2-octyl cyanoacrylate.

Authors:  Alice B W Brochu; Gregory A Evans; William M Reichert
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-08-01       Impact factor: 3.368

4.  Effects of Surface Modification and Bulk Geometry on the Biotribological Behavior of Cross-Linked Polyethylene: Wear Testing and Finite Element Analysis.

Authors:  Kenichi Watanabe; Masayuki Kyomoto; Kenichi Saiga; Shuji Taketomi; Hiroshi Inui; Yuho Kadono; Yoshio Takatori; Sakae Tanaka; Kazuhiko Ishihara; Toru Moro
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.