Literature DB >> 10793986

Tele-ophthalmology screening for retinal and anterior segment diseases.

K Yogesan1, M Cuypers, C J Barry, I J Constable, L Jitskaia.   

Abstract

A digital indirect ophthalmoscope (DIO) was developed and tested for use in tele-ophthalmology screening for posterior and anterior segment diseases. Using custom software, images from the DIO were digitized, compressed, stored and transmitted to a centralized eye clinic for interpretation. A total of 43 subjects were primarily screened for glaucoma using the DIO, a hand-held fundus camera and a stereo fundus camera. The photographic slides from the stereo fundus camera used as gold standards. Images (390 x 300 pixels x 3 bits) were stored using a laptop computer together with patient information. Image quality received at the central eye clinic was good and showed adequate diagnostic information. An ophthalmologist estimated cup-disc ratios and graded the quality of the images. The sensitivity and specificity of each instrument was calculated. A high sensitivity and specificity was found when using the DIO, indicating that it could be used in tele-ophthalmic screenings. Further modifications are needed to make the instrument more user-friendly and to enable it to be used with undilated pupils, so that it can be easily operated by health-care personnel in remote areas. The camera can also be used to image gross external eye pathology.

Entities:  

Mesh:

Year:  2000        PMID: 10793986     DOI: 10.1258/1357633001934302

Source DB:  PubMed          Journal:  J Telemed Telecare        ISSN: 1357-633X            Impact factor:   6.184


  3 in total

1.  Internet based ophthalmology service: impact assessment.

Authors:  S Kumar; M-L Tay-Kearney; I J Constable; K Yogesan
Journal:  Br J Ophthalmol       Date:  2005-10       Impact factor: 4.638

2.  Handheld shape discrimination hyperacuity test on a mobile device for remote monitoring of visual function in maculopathy.

Authors:  Yi-Zhong Wang; Yu-Guang He; Gina Mitzel; Song Zhang; Mike Bartlett
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-08-13       Impact factor: 4.799

3.  The effectiveness of teleglaucoma versus in-patient examination for glaucoma screening: a systematic review and meta-analysis.

Authors:  Sera-Melisa Thomas; Maya M Jeyaraman; Maya Jeyaraman; William G Hodge; Cindy Hutnik; John Costella; Monali S Malvankar-Mehta
Journal:  PLoS One       Date:  2014-12-05       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.