D-values were obtained for Listeria monocytogenes and Yersinia enterocolitica at 50, 55 and 60 degrees C in vacuum-packed minced beef samples heated in a laboratory water-bath. The experiment was repeated using vacutainers, which allowed heating of the beef to the desired temperature before inoculation. D-values of between 0.15 and 36.1 min were obtained for L. monocytogenes. Pre-heating the beef samples significantly affected (P < 0.05) the D60 value only. D-values for Y. enterocolitica ranged from 0.55 to 21.2 min and all the D-values were significantly different (P < 0.05) after pre-heating. In general, the D-values obtained for core inoculated solid beef samples were significantly higher (P < 0.05) than those generated in minced beef when heated in a Barriquand Steriflow commercial retort.Entities: