Literature DB >> 10791595

Assessment of indoor fine aerosol contributions from environmental tobacco smoke and cooking with a portable nephelometer.

M Brauer1, R Hirtle, B Lang, W Ott.   

Abstract

Personal monitoring studies have indicated that environmental tobacco smoke (ETS) and cooking are major indoor particulate sources in residential and nonindustrial environments. Continuous monitoring of fine particles improves exposure assessment by characterizing the effect of time-varying indoor sources. We evaluated a portable nephelometer as a continuous monitor of indoor particulate levels. Simultaneous sampling with the nephelometer and PM2.5 impactors was undertaken to determine the relationship between particle light scattering extinction coefficient (sigma(sp)) and particle mass concentration in field and environmental chamber settings. Chamber studies evaluated nephelometer measurements of ETS and particles produced from toasting bread and frying foods. Field measurements were conducted in 20 restaurants and bars with different smoking restrictions, and in five residential kitchens. Additional measurements compared the nephelometer to a different mass measurement method, a piezobalance, in a well-characterized residence where various foods were cooked and ETS was produced. Since the piezobalance provides 2-min average mass concentration measurements, these comparisons tested the ability of the nephelometer to measure transient particle concentration peaks and decay rate curves. We found that sigma(sp) and particle mass were highly correlated (R2 values of 0.63-0.98) over a large concentration range (5-1600 microg/m3) and for different particle sources. Piezobalance and gravimetric comparisons with the nephelometer indicated similar sigma(sp) vs. mass slopes (5.6 and 4.7 m2/g for piezobalance and gravimetric comparisons of ETS, respectively). Somewhat different sigma(sp) vs. particle mass slopes (1.9-5.6 m2/g) were observed for the different particle sources, reflecting the influence of particle composition on light scattering. However, in similar indoor environments, the relationship between particle light scattering and mass concentration was consistent enough to use independent nephelometer measurements as estimates of short-term mass concentrations. A method to use nephelometer measurements to determine particulate source strengths is derived and an example application is described.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10791595     DOI: 10.1038/sj.jea.7500076

Source DB:  PubMed          Journal:  J Expo Anal Environ Epidemiol        ISSN: 1053-4245


  9 in total

1.  PM1 and PM2.5 ionic composition and VOCs measurements in two typical apartments in Athens, Greece: investigation of smoking contribution to indoor air concentrations.

Authors:  Dikaia E Saraga; Thomas Maggos; Constantinos G Helmis; John Michopoulos; John G Bartzis; Christos Vasilakos
Journal:  Environ Monit Assess       Date:  2009-07-02       Impact factor: 2.513

2.  Participatory testing and reporting in an environmental-justice community of Worcester, Massachusetts: a pilot project.

Authors:  Timothy J Downs; Laurie Ross; Danielle Mucciarone; Maria-Camila Calvache; Octavia Taylor; Robert Goble
Journal:  Environ Health       Date:  2010-07-06       Impact factor: 5.984

3.  Comparison of real-time instruments and gravimetric method when measuring particulate matter in a residential building.

Authors:  Zuocheng Wang; Leonardo Calderón; Allison P Patton; MaryAnn Sorensen Allacci; Jennifer Senick; Richard Wener; Clinton J Andrews; Gediminas Mainelis
Journal:  J Air Waste Manag Assoc       Date:  2016-11       Impact factor: 2.235

4.  Attachment rate characteristics of different wide used aerosol sources in indoor air.

Authors:  Mostafa Yuness Abdelfatah Mostafa; Hyam Nazmy Bader Khalaf; Michael Zhukovsky
Journal:  J Environ Health Sci Eng       Date:  2021-04-13

5.  Discontinuous and Continuous Indoor Air Quality Monitoring in Homes with Fireplaces or Wood Stoves as Heating System.

Authors:  Gianluigi de Gennaro; Paolo Rosario Dambruoso; Alessia Di Gilio; Valerio Di Palma; Annalisa Marzocca; Maria Tutino
Journal:  Int J Environ Res Public Health       Date:  2015-12-24       Impact factor: 3.390

Review 6.  Airborne environmental injuries and human health.

Authors:  Andrea T Borchers; Christopher Chang; Carl L Keen; M Eric Gershwin
Journal:  Clin Rev Allergy Immunol       Date:  2006-08       Impact factor: 8.667

Review 7.  Peak Inhalation Exposure Metrics Used in Occupational Epidemiologic and Exposure Studies.

Authors:  M Abbas Virji; Laura Kurth
Journal:  Front Public Health       Date:  2021-01-08

8.  Incense smoke: clinical, structural and molecular effects on airway disease.

Authors:  Ta-Chang Lin; Guha Krishnaswamy; David S Chi
Journal:  Clin Mol Allergy       Date:  2008-04-25

9.  Effects of human activities on concentrations of culturable bioaerosols in indoor air environments.

Authors:  Ki Joon Heo; Cheol Eon Lim; Hannah Bae Kim; Byung Uk Lee
Journal:  J Aerosol Sci       Date:  2016-11-23       Impact factor: 3.433

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.