P L Fiori1, S Mastrandrea, P Rappelli, P Cappuccinelli.
Abstract
We report an outbreak of laboratory-acquired Brucella abortus infection originating in the accidental breakage of a centrifuge tube. A total of 12 laboratory workers were infected (attack rate of 31%), with an incubation time ranging from 6 weeks to 5 months. Antibody titers were evaluated weekly in all personnel exposed, allowing the diagnosis of the infection in most cases before the onset of clinical symptoms, so that specific therapy could be administrated.Entities:
Mesh:
Substances:
Year: 2000 PMID: 10790142 PMCID: PMC86653
Source DB: PubMed Journal: J Clin Microbiol ISSN: 0095-1137 Impact factor: 5.948