Literature DB >> 10789567

Size makes a difference: use of a low-prime cardiopulmonary bypass circuit and autologous priming in small adults.

J E Cormack1, R J Forest, R C Groom, J Morton.   

Abstract

Low hematocrit (Hct < 20) during cardiopulmonary bypass (CPB) is associated with higher mortality and other adverse outcomes. More frequently, low Hct is encountered in patients with small body size and women patients. This prompted us to take an aggressive approach in our care of these patients, involving a strategy for predicting patients at risk of low Hct, with the aid of an electronic worksheet that accurately predicts CPB Hct, and two prevention strategies: use of a low-prime CPB circuit (LP) for all adult patients with a body surface area (BSA) < 1.7 m(2) and use of autologous circuit priming (AP), in addition to the low-circuit volume in some patients. The two cohorts of patients in whom these techniques were employed were compared to a group matched for body size where our standard adult circuit (STD) was used. There were 233 patients in the standard group, 139 in the LP group, and 68 in the LP/AP group. The CPB circuit prime volume was 1,710 ml for the STD group and 1,110 ml for the LP group. Use of autologous priming techniques further reduced the prime volume by 545 +/- 139 ml. The incidence of low Hct (<20%) during CPB was thus reduced from 70% to 15% (p = 0.001) when using both techniques together without increasing red blood cell (RBC) transfusions. These changes in perfusion management resulted in a reduction in the incidence of renal complications (STD = 9.4%, LP = 6.5% (ns) and LP/AP = 0%,

Entities:  

Mesh:

Year:  2000        PMID: 10789567     DOI: 10.1177/026765910001500207

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  12 in total

1.  Understanding Off-Label Use and Reference Blood Flows in Modern Membrane Oxygenators.

Authors:  Gerard J Myers
Journal:  J Extra Corpor Technol       Date:  2014-09

2.  Early in vivo experience with the pediatric continuous-flow total artificial heart.

Authors:  Jamshid H Karimov; David J Horvath; Nicole Byram; Gengo Sunagawa; Barry D Kuban; Shengqiang Gao; Raymond Dessoffy; Kiyotaka Fukamachi
Journal:  J Heart Lung Transplant       Date:  2018-03-30       Impact factor: 10.247

Review 3.  Acute Kidney Injury Subsequent to Cardiac Surgery.

Authors:  Robert S Kramer; Crystal R Herron; Robert C Groom; Jeremiah R Brown
Journal:  J Extra Corpor Technol       Date:  2015-03

4.  Clinical evaluation of poly(2-methoxyethylacrylate) in primary coronary artery bypass grafting.

Authors:  See N Vang; Chad P Brady; Kevin A Christensen; Jack R Isler; Keith R Allen
Journal:  J Extra Corpor Technol       Date:  2005-03

5.  Net Prime Volume Is Associated with Increased Odds of Blood Transfusion.

Authors:  Timothy A Dickinson; Xiaoting Wu; David L Sturmer; Joshua Goldberg; David C Fitzgerald; Gaetano Paone; Donald S Likosky
Journal:  J Extra Corpor Technol       Date:  2019-12

6.  Lean Flow: Optimizing Cardiopulmonary Bypass Equipment and Flow for Obese Patients-A Technique Article.

Authors:  Joshua M Blessing; Jeffrey B Riley
Journal:  J Extra Corpor Technol       Date:  2017-03

7.  The Relationship between Intra-Operative Transfusions and Nadir Hematocrit on Post-Operative Outcomes after Cardiac Surgery.

Authors:  Joshua B Goldberg; Kenneth G Shann; David Fitzgerald; John Fuller; Theron A Paugh; Timothy A Dickinson; Gaetano Paone; Richard L Prager; Donald S Likosky
Journal:  J Extra Corpor Technol       Date:  2016-12

8.  The effect of retrograde autologous priming volume on haemodilution and transfusion requirements during cardiac surgery.

Authors:  Korneel Vandewiele; Thierry Bové; Filip M J J De Somer; Daniël Dujardin; Martin Vanackere; Dirk De Smet; Annelies T Moerman; Stefaan Bouchez; Katrien François
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-03-12

9.  Transfusion and bleeding in coronary artery bypass grafting: an on-pump versus off-pump comparison.

Authors:  Kieron C Potger; Darryl McMillan; Joanne Southwell; Terry Connolly; Kate Kingsford Smith; Mark Ambrose
Journal:  J Extra Corpor Technol       Date:  2007-03

10.  Influence of intraoperative fluid volume on cardiopulmonary bypass hematocrit and blood transfusions in coronary artery bypass surgery.

Authors:  Jeffrey A Campbell; David W Holt; Valerie K Shostrom; Samuel J Durham
Journal:  J Extra Corpor Technol       Date:  2008-06
View more