Literature DB >> 10788824

Transfer of patients receiving advanced mechanical circulatory support.

L R McBride1, G A Lowdermilk, A C Fiore, D A Moroney, J A Brannan, M T Swartz.   

Abstract

OBJECTIVE: Improving results with ventricular assist devices have led to their wider clinical application. Centers can stabilize, support, and wean or transfer patients to regional transplant centers.
METHODS: Prospectively collected data were reviewed to evaluate the clinical results of patients transferred to our institution while receiving advanced mechanical circulatory support.
RESULTS: Since 1993, 16 patients were accepted while receiving support with either extracorporeal membrane oxygenation or a ventricular assist device. The 10 male and 6 female patients ranged in age from 9 to 60 years (mean, 42.1 years). Thirteen had had cardiac surgical procedures, two had acute myocardial infarctions, and one had myocarditis. The distance transported ranged from 0.2 to 309 miles (mean, 132 miles). Twelve patients were transferred by ground, and 4 were transported by air. Seven patients were originally supported with extracorporeal membrane oxygenation, 6 with centrifugal pumps, and 3 with ABIOMED ventricular assist devices (ABIOMED, Inc, Danvers, Mass). Two patients had clinical complications during transfer, and one had a cerebrovascular accident, recovered, was weaned, and survived. A second patient had hemodynamic deterioration. There were no technical complications associated with transport. Six patients were left on the original support device; 3 of the 6 were weaned and survived, and 3 died during support. The 10 remaining patients were switched to other ventricular assist devices: 9 patients to Thoratec devices (Thoratec Laboratories, Pleasanton, Calif) and 1 patient to a Novacor device (Baxter Healthcare Corp, Novacor Division, Oakland, Calif). Six of the 10 patients underwent transplantation and survived. Four patients died while being supported by the devices. Nine patients were discharged, with 1 late death at 29 months. Eight patients are alive 4 to 65 months after discharge.
CONCLUSIONS: These data suggest that patients receiving advanced support can be moved between clinical centers with acceptable risks. Because 33% of the survivors were weaned, transplantation is not required for survival.

Entities:  

Mesh:

Year:  2000        PMID: 10788824     DOI: 10.1016/S0022-5223(00)70097-3

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  2 in total

1.  Mortality in children with respiratory failure transported using high-frequency oscillatory ventilation.

Authors:  Peter Jones; Stéphane Dauger; Pierre-Louis Leger; Katia Kessous; Isabelle Casadevall; Isabelle Maury; Philippe Mazeron; Noëlla Lodé
Journal:  Intensive Care Med       Date:  2015-05-14       Impact factor: 17.440

2.  Transport of critically ill children on cardiopulmonary support assistance.

Authors:  Maher K Eldadah; Monica C Olsen; Harun Fakioglu; William M DeCampli
Journal:  J Extra Corpor Technol       Date:  2010-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.