Literature DB >> 10788820

Size and distensibility of the aortic root and aortic valve function after different techniques of the ross procedure.

C Schmidtke1, J f Bechtel, M Hueppe, A Noetzold, H H Sievers.   

Abstract

OBJECTIVES: In the Ross procedure, 3 different techniques are used for aortic valve replacement with the pulmonary autograft: freestanding root, inclusion, and subcoronary implantation. The objective of this study was to evaluate echocardiographically the influence of the particular operative technique on dimension, distensibility, and valve function.
METHODS: Between February 1990 and August 1998, the Ross procedure was performed in 111 patients (mean age, 48.6 +/- 14.1 years; range, 15.2-70.6 years), with 1 early and 1 late death, 1 autograft replacement, and 1 patient lost to follow-up. The remaining patients underwent the freestanding root (n = 9 patients), inclusion (n = 14 patients), and subcoronary techniques (n = 84 patients). Echocardiography was performed at a mean follow-up of 26 +/- 21.3 months after operation and was compared with the echocardiographic findings of the control subjects (n = 10 subjects). Root sizes were measured at the level of the anulus, sinus, and supra-aortic ridge; the distensibility was calculated as pressure strain elastic modulus and percent change of radius.
RESULTS: Size and distensibility of the aortic root were normal, except for a larger diameter at the sinus level in the root technique in comparison to the subcoronary technique (P <.05; maximum diameter, 41.3 +/- 8.6 mm vs 32.6 +/- 4.0 mm). Aortic valve function was comparable among groups with low pressure gradients and most patients with no or trace aortic insufficiency.
CONCLUSIONS: The freestanding root, inclusion, and subcoronary techniques in the Ross procedure provide comparable excellent hemodynamics, normal root size, and distensibility, except for the enlarged sinus diameter in the freestanding root. These results may have some impact on the operative procedure and follow-up investigations.

Entities:  

Mesh:

Year:  2000        PMID: 10788820     DOI: 10.1016/S0022-5223(00)70094-8

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  4 in total

1.  Size and Stiffness of the Pulmonary Autograft after the Ross Procedure in Children.

Authors:  Yusuke Ando; Yoshie Ochiai; Shigehiko Tokunaga; Manabu Hisahara; Hironori Baba; Chihiro Miyagi; Tomoya Takigawa
Journal:  Pediatr Cardiol       Date:  2019-02-07       Impact factor: 1.655

2.  Wall stresses of early remodeled pulmonary autografts.

Authors:  Yue Xuan; Edgardo Alonso; Alexander Emmott; Zhongjie Wang; Shalni Kumar; Francois-Pierre Mongeon; Richard L Leask; Ismail El-Hamamsy; Liang Ge; Elaine E Tseng
Journal:  J Thorac Cardiovasc Surg       Date:  2021-08-31       Impact factor: 5.209

3.  Risk factors for neo-aortic root enlargement and aortic regurgitation following arterial switch operation.

Authors:  C J McMahon; W J Ravekes; E O'Brian Smith; S W Denfield; R H Pignatelli; C A Altman; N A Ayres
Journal:  Pediatr Cardiol       Date:  2004 Jul-Aug       Impact factor: 1.655

4.  Assessment of aortic stiffness by cardiovascular magnetic resonance following the treatment of severe aortic stenosis by TAVI and surgical AVR.

Authors:  Tarique Al Musa; Akhlaque Uddin; Timothy A Fairbairn; Laura E Dobson; Steven P Sourbron; Christopher D Steadman; Manish Motwani; Ananth Kidambi; David P Ripley; Peter P Swoboda; Adam K McDiarmid; Bara Erhayiem; James J Oliver; Daniel J Blackman; Sven Plein; Gerald P McCann; John P Greenwood
Journal:  J Cardiovasc Magn Reson       Date:  2016-06-10       Impact factor: 5.364

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.