Literature DB >> 10788818

Body surface area as a predictor of aortic and pulmonary valve diameter.

S B Capps1, R C Elkins, D M Fronk.   

Abstract

BACKGROUND: Predicting cardiac valve size from noncardiac anatomic measurements would benefit pediatric cardiologists, adult cardiologists, and cardiac surgeons in a number of decision-making situations. Previous studies correlating valve size with body size have been generated with the use of fixed autopsy specimens, angiography, and echocardiography, but primarily in the young. This study examines the relation of body surface area to measurements of the left ventricular-aortic junction (aortic valve anulus diameter) and the right ventricular-pulmonary trunk junction (pulmonary valve anulus diameter) in 6801 hearts across a wide spectrum of ages.
METHODS: From June 1985 to October 1998, cardiac valves from 6801 donated hearts were analyzed morphologically. Donor age was newborn to 59 years (mean 31 +/- 17 years; median 32 years). Calculated body surface areas ranged from 0.18 to 3.55 m(2). Aortic (n = 4636) and pulmonary valve diameters (n = 5480) were measured from enucleated valves suitable for allograft transplantation. Mean valve sizes were computed for ranges in body surface area in 0.1-m(2) increments.
RESULTS: For adult men (age >/= 17 years), the mean aortic valve diameter was 23.1 +/- 2.0 mm (n = 2214) and the mean pulmonary valve diameter was 26.2 +/- 2.3 mm (n = 2589). For adult women, the mean aortic valve diameter was 21.0 +/- 1.8 mm (n = 1156) and the mean pulmonary valve diameter was 23.9 +/- 2.2 mm (n = 1408). The mean indexed aortic valve area was 2.02 +/- 0.52 cm(2)/m(2) and the pulmonary valve area 2.65 +/- 0.52 cm(2)/m(2). Between 82% and 85% of the variability was explained by the size of the patient. Regression equations were developed both overall and separately for men and women, although the additional contribution of sex above that of body size was less than 1%.
CONCLUSIONS: Aortic and pulmonary valve diameters are closely related to body size. Thus, body surface area, when used in conjunction with other clinically accepted evaluations, is a useful tool for estimating normal aortic and pulmonary valve size.

Entities:  

Mesh:

Year:  2000        PMID: 10788818     DOI: 10.1016/S0022-5223(00)70092-4

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  21 in total

Review 1.  Annular management during aortic valve repair: a systematic review.

Authors:  Takashi Kunihara
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-11-25

2.  Aortic valve sparing operations: outcomes at 20 years.

Authors:  Tirone E David
Journal:  Ann Cardiothorac Surg       Date:  2013-01

3.  Aortic valve annular dimension in Indian population.

Authors:  Hannah Sugirthabai Rajila Rajendran; Sudha Seshayyan; Ashok Victor; Gangadevi Rajapandian
Journal:  J Clin Diagn Res       Date:  2013-09-10

4.  A geometrically adaptable heart valve replacement.

Authors:  Sophie C Hofferberth; Mossab Y Saeed; Lara Tomholt; Matheus C Fernandes; Christopher J Payne; Karl Price; Gerald R Marx; Jesse J Esch; David W Brown; Jonathan Brown; Peter E Hammer; Richard W Bianco; James C Weaver; Elazer R Edelman; Pedro J Del Nido
Journal:  Sci Transl Med       Date:  2020-02-19       Impact factor: 17.956

Review 5.  Anatomy of the aortic root: implications for aortic root reconstruction.

Authors:  Takashi Kunihara
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-06-27

Review 6.  Toward standardization of valve-sparing root replacement and annuloplasty.

Authors:  Takashi Kunihara
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-09-17

7.  Tissue-Engineered Heart Valves: A Call for Mechanistic Studies.

Authors:  Kevin M Blum; Joseph D Drews; Christopher K Breuer
Journal:  Tissue Eng Part B Rev       Date:  2018-02-13       Impact factor: 6.389

8.  Aortic valve sparing operations: a review.

Authors:  Tirone E David
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2012-08-03

9.  The association between pro-arrhythmic agents and aortic stenosis in young adults: is it sufficient to clarify the sudden unexpected deaths?

Authors:  Bojana Radnic; Nemanja Radojevic; Jelena Vucinic; Natasa Duborija-Kovacevic
Journal:  Cardiol Young       Date:  2016-11-08       Impact factor: 1.093

10.  Transesophageal Echocardiography in Healthy Young Adult Male Baboons (Papio hamadryas anubis): Normal Cardiac Anatomy and Function in Subhuman Primates Compared to Humans.

Authors:  Arthur A Bert; William B Drake; Rachael W Quinn; Kathleen M Brasky; James E O'Brien; Gary K Lofland; Richard A Hopkins
Journal:  Prog Pediatr Cardiol       Date:  2013-08-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.