Literature DB >> 10788721

Quantitative mapping of transverse relaxivity (1/T(2)) in hepatic iron overload: a single spin-echo imaging methodology.

P R Clark1, T G St Pierre.   

Abstract

Recent research into the non-invasive assessment of hepatic iron concentrations using magnetic resonance imaging has shown that the proton transverse relaxivity (1/T(2)) varies linearly with liver iron concentration. However, the development of an image-based system for the assessment of hepatic iron distribution has been confounded by the presence of motion induced artifacts in the T(2)-weighted images. We report on the development of a single spin-echo imaging methodology that enables the generation of transverse relaxivity maps over the liver. A simple smoothing technique is used to accommodate the image intensity perturbations caused by abdominal motion. The relaxivity maps are consistent with the variation of iron concentration throughout the liver. A Parzen density estimate and histogram of the relaxivity distribution are generated to assist in the visual assessment of the degree and variability of T(2) shortening with liver iron loading. It was found that one or two Gaussian functions could be used to characterize the relaxivity distributions with a small number of parameters. We propose that this methodology may be used in the clinical setting to monitor hepatic iron concentrations in the advent of an accurate transverse relaxivity calibration curve.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10788721     DOI: 10.1016/s0730-725x(00)00118-1

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  12 in total

Review 1.  Optimizing therapy for iron overload in the myelodysplastic syndromes: recent developments.

Authors:  Heather A Leitch
Journal:  Drugs       Date:  2011-01-22       Impact factor: 9.546

2.  MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients.

Authors:  John C Wood; Cathleen Enriquez; Nilesh Ghugre; J Michael Tyzka; Susan Carson; Marvin D Nelson; Thomas D Coates
Journal:  Blood       Date:  2005-04-28       Impact factor: 22.113

3.  Serum iron markers are inadequate for guiding iron repletion in chronic kidney disease.

Authors:  Paolo Ferrari; Hemant Kulkarni; Shyam Dheda; Susanne Betti; Colin Harrison; Timothy G St Pierre; John K Olynyk
Journal:  Clin J Am Soc Nephrol       Date:  2010-09-28       Impact factor: 8.237

Review 4.  Magnetic resonance imaging measurement of iron overload.

Authors:  John C Wood
Journal:  Curr Opin Hematol       Date:  2007-05       Impact factor: 3.284

5.  Limitations of using logarithmic transformation and linear fitting to estimate relaxation rates in iron-loaded liver.

Authors:  Randolph Otto; Mark R Ferguson; Kenneth Marro; John W Grinstead; Seth D Friedman
Journal:  Pediatr Radiol       Date:  2011-05-24

6.  A simulation-based comparison of two methods for determining relaxation rates from relaxometry images.

Authors:  Kenneth Marro; Randolph Otto; Orpheus Kolokythas; Akiko Shimamura; Jean E Sanders; George B McDonald; Seth D Friedman
Journal:  Magn Reson Imaging       Date:  2011-02-18       Impact factor: 2.546

7.  Reproducible MRI measurement of adipose tissue volumes in genetic and dietary rodent obesity models.

Authors:  David H Johnson; Chris A Flask; Paul R Ernsberger; Wilbur C K Wong; David L Wilson
Journal:  J Magn Reson Imaging       Date:  2008-10       Impact factor: 4.813

Review 8.  Magnetic resonance imaging assessment of excess iron in thalassemia, sickle cell disease and other iron overload diseases.

Authors:  John C Wood; Nilesh Ghugre
Journal:  Hemoglobin       Date:  2008       Impact factor: 0.849

9.  MR characterization of hepatic storage iron in transfusional iron overload.

Authors:  Haiying Tang; Jens H Jensen; Christina L Sammet; Sujit Sheth; Srirama V Swaminathan; Kristi Hultman; Daniel Kim; Ed X Wu; Truman R Brown; Gary M Brittenham
Journal:  J Magn Reson Imaging       Date:  2013-05-29       Impact factor: 4.813

10.  Preliminary evaluation of nanoscale biogenic magnetite in Alzheimer's disease brain tissue.

Authors:  D Hautot; Q A Pankhurst; N Khan; J Dobson
Journal:  Proc Biol Sci       Date:  2003-08-07       Impact factor: 5.349

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.