PURPOSE: Perigraft flow--flow outside the graft lumen but contained within the abdominal aortic aneurysm (AAA)--is a potential complication after endovascular repair of AAA. Such flow may permit AAA growth and rupture. The purpose of this study is to evaluate with computed tomography (CT) the rate of spontaneous closure of perigraft flow and the effect of persistent flow on AAA diameter.
MATERIALS AND METHODS: During a 30-month period, the authors evaluated all CT scans in 50 patients who underwent AAA repair using the Ancure endograft system. CT was performed at discharge, 6, 12, and 24 months, and at 3 months if there was perigraft flow at discharge. Scans were reviewed for the presence, size, and location of perigraft flow, and measurement of AAA diameter. Transcatheter embolization was performed on those patients with persistent leak at 6 months.
RESULTS: Sixteen (32%) of 50 patients demonstrated perigraft flow on CT performed within 72 hours of placement. Resolution of perigraft flow by 6 months was found in nine (56%) of the 16 patients, in whom AAA size had decreased in five, had increased in none, and was unchanged in four. Seven patients had persistent leaks at 6-month CT; AAA size had decreased in one, had increased in one, and was unchanged in five. In 34 patients without leaks, AAA size had decreased in nine, had increased in one, and was unchanged on 24. There was no statistically significant difference for the relationship between resolution or persistence of perigraft flow and subsequent course of AAA diameter (P = .16).
CONCLUSIONS: Although perigraft flow is frequently seen (32%) early after repair of AAA with the Ancure system, spontaneous resolution by 6 months occurs in 56% of cases. AAA size decreased in a larger percentage of patients in whom perigraft leak was absent or resolved by 6 months compared with those in whom perigraft leak persisted at 6 months.

Entities:  

Mesh:

Year:  2000        PMID: 10787200     DOI: 10.1016/s1051-0443(07)61374-8

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  1 in total

Review 1.  Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.

Authors:  Iosief Abraha; Maria Laura Luchetta; Rita De Florio; Francesco Cozzolino; Giovanni Casazza; Piergiorgio Duca; Basso Parente; Massimiliano Orso; Antonella Germani; Paolo Eusebi; Alessandro Montedori
Journal:  Cochrane Database Syst Rev       Date:  2017-06-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.