Literature DB >> 10786919

Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

R Chan1, A A Common, D Marcuzzi.   

Abstract

OBJECTIVE: To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy.
METHODS: Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major.
RESULTS: The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications.
CONCLUSIONS: Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the possibility of obtaining insufficient tissue for histologic diagnosis.

Entities:  

Mesh:

Year:  2000        PMID: 10786919

Source DB:  PubMed          Journal:  Can Assoc Radiol J        ISSN: 0846-5371            Impact factor:   2.248


  6 in total

1.  Biopsy of the transplanted kidney.

Authors:  Iftikhar Ahmad
Journal:  Semin Intervent Radiol       Date:  2004-12       Impact factor: 1.513

2.  Interventional management of renal transplant arteriovenous fistula.

Authors:  Jeanne M Laberge
Journal:  Semin Intervent Radiol       Date:  2004-12       Impact factor: 1.513

3.  Percutaneous real-time ultrasound-guided renal biopsy performed solely by nephrologists: A case series.

Authors:  S S Yesudas; N K Georgy; S Manickam; A Raheena; R C Monai; B A Noble; A Pillai
Journal:  Indian J Nephrol       Date:  2010-07

4.  Percutaneous ultrasound-guided renal biopsy: A Libyan experience.

Authors:  A Mishra; R Tarsin; B Elhabbash; N Zagan; R Markus; S Drebeka; K Abdelmola; T Shawish; A Shebani; T Abdelmola; A Elusta; E F Ehtuish
Journal:  Indian J Nephrol       Date:  2010-04

5.  Looks can be Deceiving: A Challenging Case of Anti-Neutrophil Cytoplasmic Autoantibody Associated Vasculitis.

Authors:  Bashar Ramadan; Jocelyn Taylor; Moeed Ahmed; Eric K Magliulo; Khalid Bashir
Journal:  Cureus       Date:  2021-06-24

6.  Lessons for the clinical nephrologist: ureteric obstruction secondary to blood clot after kidney biopsy.

Authors:  Daniel V O'Hara; Jeffrey K Wong; Bruce Cooper; Germaine Wong; Muh Geot Wong; Hicham Ibrahim Cheikh Hassan
Journal:  J Nephrol       Date:  2021-04-15       Impact factor: 3.902

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.