Literature DB >> 10784279

The real-time interactive 3-D-DVA for robust coronary MRA.

T S Sachs1, C H Meyer, J M Pauly, B S Hu, D G Nishimura, A Macovski.   

Abstract

A graphical user interface (GUI) has been developed which enables interactive feedback and control to the real-time diminishing variance algorithm (DVA). This interactivity allows the user to set scan parameters, view scan statistics, and view image updates during the course of the scan. In addition, the DVA has been extended to simultaneously reduce motion artifacts in three dimensions using three orthogonal navigators. Preliminary in vivo studies indicate that these improvements to the standard DVA allow for significantly improved consistency and robustness in eliminating respiratory motion artifacts from MR images, particularly when imaging the coronary arteries.

Entities:  

Mesh:

Year:  2000        PMID: 10784279     DOI: 10.1109/42.836367

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

Review 1.  Magnetic resonance coronary angiography.

Authors:  Phillip C Yang; Michael V McConnell; Dwight G Nishimura; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

2.  Free-breathing multiphase whole-heart coronary MR angiography using image-based navigators and three-dimensional cones imaging.

Authors:  Holden H Wu; Paul T Gurney; Bob S Hu; Dwight G Nishimura; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-30       Impact factor: 4.668

3.  Compressed-sensing motion compensation (CosMo): a joint prospective-retrospective respiratory navigator for coronary MRI.

Authors:  Mehdi H Moghari; Mehmet Akçakaya; Alan O'Connor; Tamer A Basha; Michele Casanova; Douglas Stanton; Lois Goepfert; Kraig V Kissinger; Beth Goddu; Michael L Chuang; Vahid Tarokh; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2011-06-10       Impact factor: 4.668

4.  Subject-specific estimation of respiratory navigator tracking factor for free-breathing cardiovascular MR.

Authors:  Mehdi H Moghari; Peng Hu; Kraig V Kissinger; Beth Goddu; Lois Goepfert; Long Ngo; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2011-08-29       Impact factor: 4.668

5.  Real-time motion correction for high-resolution larynx imaging.

Authors:  Joëlle K Barral; Juan M Santos; Edward J Damrose; Nancy J Fischbein; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2011-02-24       Impact factor: 4.668

Review 6.  Cardiac MR: From Theory to Practice.

Authors:  Tevfik F Ismail; Wendy Strugnell; Chiara Coletti; Maša Božić-Iven; Sebastian Weingärtner; Kerstin Hammernik; Teresa Correia; Thomas Küstner
Journal:  Front Cardiovasc Med       Date:  2022-03-03

7.  Free-breathing 3D cardiac MRI using iterative image-based respiratory motion correction.

Authors:  Mehdi H Moghari; Sébastien Roujol; Raymond H Chan; Susie N Hong; Natalie Bello; Markus Henningsson; Long H Ngo; Beth Goddu; Lois Goepfert; Kraig V Kissinger; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-11-06       Impact factor: 4.668

8.  A respiratory self-gating technique with 3D-translation compensation for free-breathing whole-heart coronary MRA.

Authors:  Peng Lai; Xiaoming Bi; Renate Jerecic; Debiao Li
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.