True arterial system compliance estimated from apparent arterial compliance.

C M Quick1, D S Berger, D A Hettrick, A Noordergraaf.   

Abstract

A new method has been developed to estimate total arterial compliance from measured input pressure and flow. In contrast to other methods, this method does not rely on fitting the elements of a lumped model to measured data. Instead, it relies on measured input impedance and peripheral resistance to calculate the relationship of arterial blood volume to input pressure. Generally, this transfer function is a complex function of frequency and is called the apparent arterial compliance. At very low frequencies, the confounding effect of pulse wave reflection disappears, and apparent compliance becomes total arterial compliance. This study reveals that frequency components of pressure and flow below heart rate are generally necessary to obtain a valid estimate of compliance. Thus, the ubiquitous practice of estimating total arterial compliance from a single cardiac cycle is suspect under most circumstances, since a single cardiac cycle does not contain these frequencies.

Mesh:

Year:  2000        PMID: 10784093     DOI: 10.1114/1.268

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  6 in total

Review 1.  Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis.

Authors:  Ramakrishna Mukkamala; Da Xu
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-07-09       Impact factor: 4.733

2.  Increasing pulse wave velocity in a realistic cardiovascular model does not increase pulse pressure with age.

Authors:  Mohammad W Mohiuddin; Ryan J Rihani; Glen A Laine; Christopher M Quick
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-05-04       Impact factor: 4.733

3.  Assessment of Fractional-Order Arterial Windkessel as a Model of Aortic Input Impedance.

Authors:  Mohamed A Bahloul; Taous-Meriem Laleg-Kirati
Journal:  IEEE Open J Eng Med Biol       Date:  2020-04-22

4.  A non-invasive assessment of cardiopulmonary hemodynamics with MRI in pulmonary hypertension.

Authors:  Octavia Bane; Sanjiv J Shah; Michael J Cuttica; Jeremy D Collins; Senthil Selvaraj; Neil R Chatterjee; Christoph Guetter; James C Carr; Timothy J Carroll
Journal:  Magn Reson Imaging       Date:  2015-08-14       Impact factor: 2.546

5.  Frequency-resolved analysis of coherent oscillations of local cerebral blood volume, measured with near-infrared spectroscopy, and systemic arterial pressure in healthy human subjects.

Authors:  Kristen Tgavalekos; Thao Pham; Nishanth Krishnamurthy; Angelo Sassaroli; Sergio Fantini
Journal:  PLoS One       Date:  2019-02-12       Impact factor: 3.240

6.  Human Hypertension Blood Flow Model Using Fractional Calculus.

Authors:  Mohamed A Bahloul; Yasser Aboelkassem; Taous-Meriem Laleg-Kirati
Journal:  Front Physiol       Date:  2022-03-22       Impact factor: 4.566

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.