Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction.

C H Yan1, R T Whalen, G S Beaupré, S Y Yen, S Napel.   

Abstract

This paper presents a new reconstruction algorithm for both single- and dual-energy computed tomography (CT) imaging. By incorporating the polychromatic characteristics of the X-ray beam into the reconstruction process, the algorithm is capable of eliminating beam hardening artifacts. The single energy version of the algorithm assumes that each voxel in the scan field can be expressed as a mixture of two known substances, for example, a mixture of trabecular bone and marrow, or a mixture of fat and flesh. These assumptions are easily satisfied in a quantitative computed tomography (QCT) setting. We have compared our algorithm to three commonly used single-energy correction techniques. Experimental results show that our algorithm is much more robust and accurate. We have also shown that QCT measurements obtained using our algorithm are five times more accurate than that from current QCT systems (using calibration). The dual-energy mode does not require any prior knowledge of the object in the scan field, and can be used to estimate the attenuation coefficient function of unknown materials. We have tested the dual-energy setup to obtain an accurate estimate for the attenuation coefficient function of K2 HPO4 solution.

Entities:  

Keywords:  NASA Center ARC; NASA Discipline Musculoskeletal; NASA Program Biomedical Research and Countermeasures

Mesh:

Year:  2000        PMID: 10782614     DOI: 10.1109/42.832955

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  18 in total

1.  In situ parameter identification of optimal density-elastic modulus relationships in subject-specific finite element models of the proximal femur.

Authors:  Alexander Cong; Jorn Op Den Buijs; Dan Dragomir-Daescu
Journal:  Med Eng Phys       Date:  2010-10-27       Impact factor: 2.242

2.  Noise-resolution tradeoffs in x-ray CT imaging: a comparison of penalized alternating minimization and filtered backprojection algorithms.

Authors:  Joshua D Evans; David G Politte; Bruce R Whiting; Joseph A O'Sullivan; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

3.  Non-convexly constrained image reconstruction from nonlinear tomographic X-ray measurements.

Authors:  Thomas Blumensath; Richard Boardman
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2015-06-13       Impact factor: 4.226

4.  A digitally reconstructed radiograph algorithm calculated from first principles.

Authors:  David Staub; Martin J Murphy
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

5.  Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

6.  In vivo longitudinal assessment of bone resorption in a fibular osteotomy model using micro-computed tomography.

Authors:  Kim A Powell; Larry Latson; Michael O Ibiwoye; Alan Wolfman; Mark D Grabiner; Maciej Zborowski; Yoshitada Sakai; Ronald J Midura
Journal:  Iowa Orthop J       Date:  2005

7.  Simplified Statistical Image Reconstruction for X-ray CT With Beam-Hardening Artifact Compensation.

Authors:  Monica Abella; Cristobal Martinez; Manuel Desco; Juan Jose Vaquero; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2019-06-10       Impact factor: 10.048

8.  Specimen size and porosity can introduce error into microCT-based tissue mineral density measurements.

Authors:  Roberto J Fajardo; Esther Cory; Nipun D Patel; Ara Nazarian; Andres Laib; Rajaram K Manoharan; James E Schmitz; Jeremy M DeSilva; Laura M MacLatchy; Brian D Snyder; Mary L Bouxsein
Journal:  Bone       Date:  2008-09-10       Impact factor: 4.398

9.  Experimental implementation of a polyenergetic statistical reconstruction algorithm for a commercial fan-beam CT scanner.

Authors:  Joshua D Evans; Bruce R Whiting; David G Politte; Joseph A O'Sullivan; Paul F Klahr; Jeffrey F Williamson
Journal:  Phys Med       Date:  2013-01-21       Impact factor: 2.685

10.  Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.

Authors:  Jeffrey A Meganck; Kenneth M Kozloff; Michael M Thornton; Stephen M Broski; Steven A Goldstein
Journal:  Bone       Date:  2009-08-06       Impact factor: 4.398

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.