Electromagnetic interference with electronic medical equipment induced by automatic conveyance systems.

E Hanada1, Y Watanabe, Y Nose.   

Abstract

Electromagnetic interference (EMI) with electronic medical equipment induced by automatic conveyance systems is estimated. We measured the electric intensities of electromagnetic waves transmitted by three self-controlled electric truck systems. We also observed EMI with an infusion pump and a syringe pump set 1 m from the rail. The maximum electric field intensity was observed at the supplied current frequency in two systems with non-contact power supply mechanisms. The highest value, 137.0 dB microV/m, was measured just beside the rail. This is higher than the international electromagnetic immunity standard limit for electronic medical equipment. EMI may occur if electronic medical equipment is used within 2 m of the rail when the system contains an inductive power supply mechanism. With a contact power supply mechanism, the electric field intensity was much lower than that of the immunity standard. EMI should not occur even when electronic medical equipment is used just beside the rail.

Entities:  

Mesh:

Year:  2000        PMID: 10782439     DOI: 10.1023/a:1005424910489

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  4 in total

1.  Medical device adverse events and electromagnetic interference.

Authors:  D Dwyer
Journal:  Int J Trauma Nurs       Date:  1999 Jan-Mar

2.  Automating the drug distribution system.

Authors:  S M Somani; T W Woller
Journal:  Top Hosp Pharm Manage       Date:  1989-05

3.  Hospital construction materials: poor shielding capacity with respect to signals transmitted by mobile telephones.

Authors:  E Hanada; Y Watanabe; Y Antoku; Y Kenjo; H Nutahara; Y Nose
Journal:  Biomed Instrum Technol       Date:  1998 Sep-Oct

4.  Radiofrequency interference with medical devices. A technical information statement.

Authors: 
Journal:  IEEE Eng Med Biol Mag       Date:  1998 May-Jun
  4 in total
  2 in total

1.  A practical procedure to prevent electromagnetic interference with electronic medical equipment.

Authors:  Eisuke Hanada; Kyoko Takano; Yasuaki Antoku; Kouji Matsumura; Yoshiaki Watanabe; Yoshiaki Nose
Journal:  J Med Syst       Date:  2002-02       Impact factor: 4.460

2.  A Multi-Constraint Scheme with Authorized Mechanism for the Patient Safety.

Authors:  Jen-Ming Hsu; Yao-Chang Yu; Ting-Wei Hou; Wei-Guang Teng; Tzu-Chiang Chiang; Ming-Chang Yang
Journal:  J Med Syst       Date:  2016-04-02       Impact factor: 4.460

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.