Literature DB >> 10781661

Comparison of the efficacy of two air-based contrast agents in dogs.

R Uchimoto1, K Niwa, N Tsuda, T Miyazawa, M Bräutigam.   

Abstract

OBJECTIVE: The aim of this study was to evaluate the differences of the in vivo efficacies of Levovist(SH U 508 A) and Albunex, air-based contrast agents (CAs) with different shell materials, by direct comparison.
METHODS: SH U 508 A, 300 mg/ml, and Albunex were injected intravenously at doses of 0.1 and 0.15 ml/kg, respectively, into the same dogs (n=6). Contrast enhancement in the left ventricle was evaluated visually and by off-line measurement of brightness.
RESULTS: Both CAs yielded good peak contrast, while the duration of contrast enhancement with SH U 508 A was seven times that with Albunex. With Albunex, reduction of contrast enhancement at end-systole and in the late phase of diastole during one heartbeat was observed, and a positive correlation was observed between contrast enhancement and heart rate. Contrast enhancement was nearly constant during one heartbeat with SH U 508 A.
CONCLUSION: SH U 508 A yielded consistent and longer contrast enhancement in the left ventricle than Albunex under the same conditions.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10781661     DOI: 10.1016/s0929-8266(00)00079-3

Source DB:  PubMed          Journal:  Eur J Ultrasound        ISSN: 0929-8266


  2 in total

1.  Use of the galactose-based contrast agent SHU 508A (Levovist) in renal ultrasonography of the dog.

Authors:  M Pietra; E Brini; F Fracassi; A Diana; M Cipone
Journal:  Vet Res Commun       Date:  2005-08       Impact factor: 2.459

2.  Quantitative contrast-enhanced ultrasound imaging: a review of sources of variability.

Authors:  M-X Tang; H Mulvana; T Gauthier; A K P Lim; D O Cosgrove; R J Eckersley; E Stride
Journal:  Interface Focus       Date:  2011-05-18       Impact factor: 3.906