Literature DB >> 10779109

Analysis of arm trajectories of everyday tasks for the development of an upper-limb orthosis.

R Ramanathan1, S P Eberhardt, T Rahman, W Sample, R Seliktar, M Alexander.   

Abstract

Spatiotemporal arm and body movements of able-bodied subjects performing nine everyday tasks were recorded for the purpose of guiding the development of an upper-limb orthosis. To provide a user the opportunity to carry out these tasks with natural movements, the orthosis should allow replication of the measured trajectories. We outline the orthosis architecture, which supports the user's upper arm and forearm, and analyze the movement data to obtain orthosis design specifications. Trajectories were obtained using six-degree-of-freedom magnetic position sensors affixed to the wrist, elbow, shoulder, trunk and head. Elbow trajectory data were decomposed into ranges along the principle Cartesian axes to provide a generally useful envelope measure. The smallest Cartesian parallel-piped that contained the elbow trajectories for most tasks was approximately 30 cm front/back, 15 cm side/side, and 17 cm up/down. A rough lower bound estimate obtained by asking subjects to repeat the tasks while minimizing elbow movement substantially reduced movement in the up/down and side/side dimensions. Elbow angles were generally in the range 50 degrees-150 degrees, and the angle of the forearm with respect to vertical was 10 degrees-110 degrees. Raw trajectory data may be downloaded from www://asel.udel.edu/robotics/orthosis/range.h tml.

Entities:  

Mesh:

Year:  2000        PMID: 10779109     DOI: 10.1109/86.830950

Source DB:  PubMed          Journal:  IEEE Trans Rehabil Eng        ISSN: 1063-6528


  3 in total

1.  Development of a prosthesis shoulder mechanism for upper limb amputees: application of an original design methodology to optimize functionality and wearability.

Authors:  Marco Troncossi; Corrado Borghi; Marco Chiossi; Angelo Davalli; Vincenzo Parenti-Castelli
Journal:  Med Biol Eng Comput       Date:  2009-03-03       Impact factor: 2.602

2.  A novel five degree of freedom user command controller in people with spinal cord injury and non-injured for full upper extremity neuroprostheses, wearable powered orthoses and prosthetics.

Authors:  Timothy R D Scott; Veronica A Vare
Journal:  Med Biol Eng Comput       Date:  2012-12-13       Impact factor: 2.602

3.  Preferred Placement and Usability of a Smart Textile System vs. Inertial Measurement Units for Activity Monitoring.

Authors:  Mohammad Iman Mokhlespour Esfahani; Maury A Nussbaum
Journal:  Sensors (Basel)       Date:  2018-08-01       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.