Literature DB >> 10775817

Accuracy of dobutamine tetrofosmin myocardial perfusion imaging for the noninvasive diagnosis of transplant coronary artery stenosis.

A Elhendy1, F B Sozzi, R T van Domburg, P Vantrimpont, R Valkema, E P Krenning, J R Roelandt, L P Maat, A H Balk.   

Abstract

BACKGROUND: Exercise stress myocardial perfusion scintigraphy has been used for the diagnosis of transplant coronary artery stenosis (TCAS) in cardiac allograft recipients. However, the role of pharmacologic stress myocardial perfusion imaging has not been evaluated. Aim of the study is to assess the accuracy of dobutamine stress 99m technetium tetrofosmin myocardial perfusion imaging for the diagnosis of TCAS in heart transplant recipients. PATIENTS AND METHODS: We studied 50 patients (age 56 +/- 8 year, 45 men) at a mean of 6.4 +/- 2.8 years after cardiac transplant with dobutamine (up to 40 ìg/kg/min) stress 99m technetium tetrofosmin SPECT. Resting images were acquired 24 hours after the stress study. Significant TCAS was defined as > or =50% luminal diameter stenosis by coronary angiography.
RESULTS: Significant TCAS was detected in 30 patients (60%). Myocardial perfusion abnormalities (reversible and/or fixed defects) were detected in 27 of the 30 patients with and in 9 of the 20 patients without significant TCAS (sensitivity = 90%, CI 82-98, specificity = 55% CI 41-69, positive predictive value = 75%, CI 63-87, negative predictive value = 79%, CI 67-90 and accuracy = 76%, CI 64-88). Patients with multivessel TCAS had a larger stress perfusion defect score (5.6 +/- 3.1 vs 3.2 +/- 2.4, p < 0.05) compared to patients with single vessel TCAS. Among patients with abnormal perfusion who had no significant TCAS, 2 had lesions <50%, 2 had luminal irregularities and 5 had no abnormalities at angiography. Therefore specificity was 62% (8/13) in patients without any detectable angiographic abnormalities.
CONCLUSIONS: Dobutamine stress tetrofosmin myocardial perfusion imaging is a highly sensitive method for the detection of TCAS in recipients of cardiac allografts. The high negative predictive value of the test indicates that patients who demonstrate normal perfusion by this method may be excluded from further invasive studies.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10775817     DOI: 10.1016/s1053-2498(00)00068-1

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  9 in total

1.  Patient-centered imaging.

Authors:  E Gordon Depuey; John J Mahmarian; Todd D Miller; Andrew J Einstein; Christopher L Hansen; Thomas A Holly; Edward J Miller; Donna M Polk; L Samuel Wann
Journal:  J Nucl Cardiol       Date:  2012-04       Impact factor: 5.952

Review 2.  Transplant allograft vasculopathy: Role of multimodality imaging in surveillance and diagnosis.

Authors:  Gregory A Payne; Fadi G Hage; Deepak Acharya
Journal:  J Nucl Cardiol       Date:  2015-12-28       Impact factor: 5.952

Review 3.  Imaging in patients after cardiac transplantation and in patients with ventricular assist devices.

Authors:  Bhanu Gupta; Dany Jacob; Randall Thompson
Journal:  J Nucl Cardiol       Date:  2015-04-02       Impact factor: 5.952

4.  Diagnostic and prognostic value of myocardial perfusion gated SPECT in orthotopic heart transplant recipients.

Authors:  Alain Manrique; Mathieu Bernard; Anne Hitzel; Michael Bubenheim; Christophe Tron; Denis Agostini; Alain Cribier; Pierre Véra; Jean Paul Bessou; Michel Redonnet
Journal:  J Nucl Cardiol       Date:  2010-02-12       Impact factor: 5.952

5.  New developments for the detection and treatment of cardiac vasculopathy.

Authors:  Kevin J Clerkin; Ziad A Ali; Donna M Mancini
Journal:  Curr Opin Cardiol       Date:  2017-02-15       Impact factor: 2.161

Review 6.  Diagnosis and management of coronary allograft vasculopathy in children and adolescents.

Authors:  Nathalie Dedieu; Gerald Greil; James Wong; Matthew Fenton; Michael Burch; Tarique Hussain
Journal:  World J Transplant       Date:  2014-12-24

7.  Prediction of long-term (> 10 year) cardiovascular outcomes in heart transplant recipients: Value of stress technetium-99m tetrofosmin myocardial perfusion imaging.

Authors:  Jesse F Veenis; Hendrik J Boiten; Jan C van den Berge; Kadir Caliskan; Alex P W M Maat; Roelf Valkema; Alina A Constantinescu; Olivier C Manintveld; Felix Zijlstra; Ron T van Domburg; Arend F L Schinkel
Journal:  J Nucl Cardiol       Date:  2017-11-07       Impact factor: 5.952

8.  Clinical Utility of SPECT in the Heart Transplant Population: Analysis From a Single Large-volume Center.

Authors:  Jack Aguilar; Robert J H Miller; Yuka Otaki; Balaji Tamarappoo; Sean Hayes; John Friedman; Piotr J Slomka; Louise E J Thomson; Michelle Kittleson; Jignesh K Patel; Jon A Kobashigawa; Daniel S Berman
Journal:  Transplantation       Date:  2022-03-01       Impact factor: 5.385

9.  Toxoplasma gondii serostatus is not associated with impaired long-term survival after heart transplantation.

Authors:  Jaap J van Hellemond; Ron T van Domburg; Kadir Caliskan; Ozcan Birim; Aggie H Balk
Journal:  Transplantation       Date:  2013-12-27       Impact factor: 4.939

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.