Literature DB >> 10773367

High-frequency ultrasound for quantitative characterization of myocardial edema.

C L Dent1, M J Scott, S A Wickline, C S Hall.   

Abstract

Myocardial edema has been associated with impaired ventricular compliance and diastolic filling. To determine the sensitivity of high-frequency (40 MHz) ultrasound to myocardial edema, we employed a model in which myocardial edema was induced by immersion of tissue in isotonic saline. The effect of freezing tissue on edema formation was also evaluated. Rat hearts were arrested at end-diastole and insonified fresh within 15 min of excision (n = 5) or following being frozen for 24 h and thawed (n = 4). Measurements of attenuation, backscatter, tissue thickness and speed of sound were performed at baseline and hourly for 4 h, and compared with direct measurements of myocardial edema. Fresh tissue demonstrated a greater propensity for the development of edema than frozen tissue. Integrated backscatter increased in both tissues, whereas the magnitude and slope of attenuation decreased as edema evolved. We conclude that high-frequency ultrasound sensitively detects myocardial edema, and we propose that the extension of these methods to clinical frequencies may prove useful for monitoring and treatment of cardiac edematous disease states.

Entities:  

Mesh:

Year:  2000        PMID: 10773367     DOI: 10.1016/s0301-5629(99)00144-1

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

Review 1.  Myocardial microvascular permeability, interstitial oedema, and compromised cardiac function.

Authors:  Ranjeet M Dongaonkar; Randolph H Stewart; Hans J Geissler; Glen A Laine
Journal:  Cardiovasc Res       Date:  2010-05-13       Impact factor: 10.787

2.  Poly(vinyl alcohol) gel ultrasound phantom with durability and visibility of internal flow.

Authors:  Kenichi Funamoto; Osamu Yamashita; Toshiyuki Hayase
Journal:  J Med Ultrason (2001)       Date:  2014-08-05       Impact factor: 1.314

Review 3.  T2-weighted cardiovascular magnetic resonance in acute cardiac disease.

Authors:  Ingo Eitel; Matthias G Friedrich
Journal:  J Cardiovasc Magn Reson       Date:  2011-02-18       Impact factor: 5.364

Review 4.  Myocardial Fluid Balance and Pathophysiology of Myocardial Edema in Coronary Artery Bypass Grafting.

Authors:  Rita Zahara; Anwar Santoso; Adhiala Z Barano
Journal:  Cardiol Res Pract       Date:  2020-05-20       Impact factor: 1.866

5.  Spatiotemporal Coherence Weighting for In Vivo Cardiac Photoacoustic Image Beamformation.

Authors:  Rashid Al Mukaddim; Tomy Varghese
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

6.  An inverse finite element method for determining the tissue compressibility of human left ventricular wall during the cardiac cycle.

Authors:  Abdallah I Hassaballah; Mohsen A Hassan; Azizi N Mardi; Mohd Hamdi
Journal:  PLoS One       Date:  2013-12-19       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.