Literature DB >> 10773327

Evaluation of floating and sticking extended release delivery systems: an unconventional dissolution test.

T Dürig1, R Fassihi.   

Abstract

The extent to which hydrophilic matrix tablets with a propensity to stick to the dissolution apparatus and/or float are susceptible to variations in hydrodynamic conditions during dissolution testing was investigated. Furthermore the usefulness of simple alternatives to the current compendial tests is examined. Swellable hydrocolloid (guar) matrix tablets containing verapamil HCl were evaluated using USP dissolution apparatus I and II. Two additional configurations where an additional single ring and mesh device or a double mesh device was located below the paddle in the dissolution vessel were also evaluated. Tablets were placed on top of the single mesh device or in the compartment formed by the two mesh surfaces of the double mesh device. In all cases near linear (n>/=0.82) release profiles were observed. When using apparatus I it was observed that the highly swellable tablets were fully constricted by the basket within 5-7 h. This prevented further independent movement and unimpeded swelling and coincided with a departure from linear release and increased variability (S.D.</=9.5%). Under standard apparatus II conditions two out of three tablets adhered to the bottom of the dissolution vessel for the duration of the experiment. Consequently their release profiles differed markedly from those obtained under apparatus I conditions (similarity factor, f(2)=30.5) with the release rate being approximately half of that obtained under apparatus I conditions. Adhesion to the dissolution vessel was also observed when paddle speed was doubled to 100 rpm, thus again resulting in large variability (S.D.</=34%). Whilst the averaged single and double mesh configuration profiles were similar to the apparatus I profile (f(2)=57.36 and 61.38, respectively), large variability (S.D.</=11%) occurred with the single mesh configuration due to floating and random adhesion of tablets to the paddle or sampling tubes. Almost superimposable profiles were obtained for the individual tablets (S.D.<3%) when the tablets were located in the compartment formed by the double mesh device. Use of a double mesh device may therefore provide an alternative to current compendial dissolution methods when the reliable determination of the true release kinetics of floating and sticking delivery systems is desired.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10773327     DOI: 10.1016/s0168-3659(00)00194-2

Source DB:  PubMed          Journal:  J Control Release        ISSN: 0168-3659            Impact factor:   9.776


  8 in total

1.  Evaluation of the impacts of formulation variables and excipients on the drug release dynamics of a polyamide 6,10-based monolithic matrix using mathematical tools.

Authors:  Oluwatoyin A Adeleke; Yahya E Choonara; Pradeep Kumar; Lisa C du Toit; Lomas K Tomar; Charu Tyagi; Viness Pillay
Journal:  AAPS PharmSciTech       Date:  2013-08-30       Impact factor: 3.246

2.  Comparison of three dissolution apparatuses for testing calcium phosphate pellets used as ibuprofen delivery systems.

Authors:  Emilie Chevalier; Marylène Viana; Aymeric Artaud; Lisette Chomette; Samir Haddouchi; Gille Devidts; Dominique Chulia
Journal:  AAPS PharmSciTech       Date:  2009-05-14       Impact factor: 3.246

3.  Development and evaluation of sustained release gastroretentive minimatrices for effective treatment of H. pylori infection.

Authors:  Atul C Badhan; Rajashree C Mashru; Punit P Shah; Arti R Thakkar; Nitin B Dobaria
Journal:  AAPS PharmSciTech       Date:  2009-04-21       Impact factor: 3.246

4.  A novel approach in distinguishing between role of hydrodynamics and mechanical stresses similar to contraction forces of GI tract on drug release from modified release dosage forms.

Authors:  Majde Takieddin; Reza Fassihi
Journal:  AAPS PharmSciTech       Date:  2014-10-02       Impact factor: 3.246

5.  Intragastric floating drug delivery system of cefuroxime axetil: in vitro evaluation.

Authors:  Viral F Patel; Natavarlal M Patel
Journal:  AAPS PharmSciTech       Date:  2006-02-24       Impact factor: 3.246

Review 6.  In Vitro and In Vivo Test Methods for the Evaluation of Gastroretentive Dosage Forms.

Authors:  Felix Schneider; Mirko Koziolek; Werner Weitschies
Journal:  Pharmaceutics       Date:  2019-08-16       Impact factor: 6.321

7.  FDM 3D-Printed Sustained-Release Gastric-Floating Verapamil Hydrochloride Formulations with Cylinder, Capsule and Hemisphere Shapes, and Low Infill Percentage.

Authors:  Haonan Qian; Di Chen; Xiangyu Xu; Rui Li; Guangrong Yan; Tianyuan Fan
Journal:  Pharmaceutics       Date:  2022-01-25       Impact factor: 6.321

8.  High-amylose sodium carboxymethyl starch matrices: development and characterization of tramadol hydrochloride sustained-release tablets for oral administration.

Authors:  Teresa Nabais; Grégoire Leclair
Journal:  ISRN Pharm       Date:  2014-04-08
  8 in total