Literature DB >> 10771975

Neonatal mechanical ventilation--experience at a level II care centre.

S Nangia1, A Saili, A K Dutta, V Gaur, M Singh, A Seth, S Kumari.   

Abstract

One hundred and fifty nine neonates were ventilated over a period of one year of whom 74 (46.54%) survived. This study aims to analyse the indications, complications and outcome of babies requiring mechanical ventilation. The early outcome measures were (i) survival rate with respect to birth weight, gestation and indication of ventilation, and (ii) Complications of assisted ventilation. One hundred and forty seven babies received IPPV and 34 received CPAP. Twenty two out of these 34 required IPPV later. Survival was cent percent on exclusive CPAP mode. HMD was the commonest indication for ventilation followed by Birth asphyxia, Apnea of prematurity, Meconium Aspiration Syndrome and Persistent Pulmonary Hypertension of the New born. Survival rates increased with increasing birth weight and gestational age, changing from 25% for < 1000 gm and 20% for < 28 wks to 53% for > 2500 gms and 50.2% for > 37 wks. Prolonged ventilatory support was needed for HMD (mean 114 hrs) and PPHN (mean 156 hrs). Commonest complication was Sepsis (26%) followed by Pulmonary hemorrhage, Pneumothorax and IVH. Lower success rates in ventilation is due to the poor survival of babies weighing < 1000 gms and those with a gestation of < 28 wks with nosocomial infections as a major complication of assisted ventilation being an additional factor.

Entities:  

Mesh:

Year:  1998        PMID: 10771975     DOI: 10.1007/BF02752306

Source DB:  PubMed          Journal:  Indian J Pediatr        ISSN: 0019-5456            Impact factor:   1.967


  12 in total

Review 1.  Assisted ventilation in neonates: the Indian perspective.

Authors:  O N Bhakoo
Journal:  Indian Pediatr       Date:  1995-12       Impact factor: 1.411

2.  Mechanical ventilation of the newborn.

Authors:  W Tarnow-Mordi; A Wilkinson
Journal:  Br Med J (Clin Res Ed)       Date:  1986-03-01

3.  Continuous positive airway pressure with a face-mask in infants with hyaline membrane disease.

Authors:  M V Murali; D Ray; V K Paul; A K Deorari; M Singh
Journal:  Indian Pediatr       Date:  1988-07       Impact factor: 1.411

4.  Mechanical ventilation of newborns: experience from a level II NICU.

Authors:  P P Maiya; D Vishwanath; S Hegde; T P Srinivas; C C Shantala; P Umakumaran; B Naveen; R K Hegde
Journal:  Indian Pediatr       Date:  1995-12       Impact factor: 1.411

5.  Mechanical ventilation of newborn infants. V. Five years' experience.

Authors:  W J Daily; P Sunshine; P C Smith
Journal:  Anesthesiology       Date:  1971-02       Impact factor: 7.892

6.  Three-year experience with neonatal ventilation from a tertiary care hospital in Delhi.

Authors:  M Singh; A K Deorari; V K Paul; M Mittal; S Shanker; U Munshi; Y Jain
Journal:  Indian Pediatr       Date:  1993-06       Impact factor: 1.411

7.  Improved survival of ventilated neonates with modern intensive care.

Authors:  R L Schreiner; J A Kisling; G M Evans; S Phillips; J A Lemons; E L Gresham
Journal:  Pediatrics       Date:  1980-12       Impact factor: 7.124

8.  Mechanical ventilation in newborn infants.

Authors:  J Kishan; M E Valdez; N A Mir; A Y Elzouki
Journal:  Afr J Med Med Sci       Date:  1988-06

9.  Persistent pulmonary arterial hypertension of the newborn.

Authors:  A Narang; O N Bhakoo; P M Nair; V Bhandari
Journal:  Indian J Pediatr       Date:  1992 Nov-Dec       Impact factor: 1.967

10.  Assisted ventilation in neonates: the Manipal experience.

Authors:  L Krishnan; P P Francis; N A D'Souza; N Bhaskaranand
Journal:  Indian J Pediatr       Date:  1994 Jul-Aug       Impact factor: 1.967

View more
  4 in total

1.  Conventional ventilation in neonates: experience from Saudi Arabia.

Authors:  G Karthikeyan; Mohammad Mosharoff Hossain
Journal:  Indian J Pediatr       Date:  2002-01       Impact factor: 1.967

2.  An experience with neonatal ventilation in eastern U.P.

Authors:  Ruchi Rai; D K Singh
Journal:  Indian J Pediatr       Date:  2009-11       Impact factor: 1.967

3.  Neonatal mechanical ventilation.

Authors:  P K Riyas; K M Vijayakumar; M L Kulkarni
Journal:  Indian J Pediatr       Date:  2003-07       Impact factor: 1.967

4.  Neonatal mechanical ventilation: Indications and outcome.

Authors:  Qazi Iqbal; Mir M Younus; Asif Ahmed; Ikhlas Ahmad; Javed Iqbal; Bashir A Charoo; S Wajid Ali
Journal:  Indian J Crit Care Med       Date:  2015-09
  4 in total