Literature DB >> 10771077

Surface EMG-recordings using a miniaturised matrix electrode: a new technique for small animals.

F Biedermann1, N P Schumann, M S Fischer, H C Scholle.   

Abstract

A new method for multichannel surface-EMG measurements in small animals is presented. The underlying scientific aim is the characterisation of the spreading and the co-ordination of skeletal muscle activation between different muscles or muscle parts, depending on various motor tasks. The myoelectrical signals were recorded monopolarly by a 16-channel matrix electrode on the muscle surface directly under the skin on the fascia of the investigated muscle, without damaging the muscle. Surface-EMG's were recorded for at least 5 days after surgery without electrical interferences. During defined motor tasks, the projection of the myoelectrical activation of the different parts of the M. triceps brachii of rats (Rattus norvegicus), pikas (Ochotona rufescens) and cuis (Galea musteloides) or the M. anconeus of toads (Bufo marinus) on the muscle surface was mapped. The locomotion of the investigated animals was monitored by a three-dimensional kinematic analysis (video and/or high-speed cineradiography). There was no perceptible influence from application of EMG matrix electrode. The miniaturised matrix electrode seemed practicable in gaining insight into changes in myoelectrical activation patterns (EMG mapping). This allows a characterisation of the intramuscular co-ordination processes corresponding to the actual morphofunctional state of the investigated animals.

Entities:  

Mesh:

Year:  2000        PMID: 10771077     DOI: 10.1016/s0165-0270(00)00170-9

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  3 in total

1.  Kinematic and electromyographic tools for characterizing movement disorders in mice.

Authors:  Hans C Scholle; H A Jinnah; Dirk Arnold; Frank H W Biedermann; Bernd Faenger; Roland Grassme; Ellen J Hess; Nikolaus P Schumann
Journal:  Mov Disord       Date:  2010-02-15       Impact factor: 10.338

2.  Comparison between Intramuscular Multichannel Electrodes and Supramysial Multichannel Electrodes via EMG Measurements for Potential Use as Larynx Stimulation Electrodes: In Vivo Animal Analysis.

Authors:  Bernd Faenger; Nikolaus P Schumann; Christoph Anders; Dirk Arnold; Roland Grassme; Orlando Guntinas-Lichius; Hans-Christoph Scholle
Journal:  Sensors (Basel)       Date:  2019-10-16       Impact factor: 3.576

3.  Chronic Multi-Electrode Electromyography in Snakes.

Authors:  Grady W Jensen; Patrick van der Smagt; Harald Luksch; Hans Straka; Tobias Kohl
Journal:  Front Behav Neurosci       Date:  2022-01-07       Impact factor: 3.558

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.