Literature DB >> 10768719

Complete denture wearers: electromyography of mastication and texture perception whilst eating meat.

J L Veyrune1, L Mioche.   

Abstract

This study was undertaken to evaluate the sensitivity of denture wearers to different food textures and to follow masticatory pattern adaptation with variation in texture using electromyography (EMG) recordings. Nine patients with complete dentures and 9 dentate control patients without any oro-dental pathology were studied. Six different samples of beef were obtained from the same muscle by altering the state of the muscle fibres and by variation of the cooking temperature. The variations in texture were mechanically controlled. Electromyographic activity was recorded during chewing. The patients' subjective appreciation of texture was reported using a 10-cm non-structured analogue scale. The following parameters were analysed: muscle work, number of masticatory cycles, number of rejected samples, initial tenderness, overall tenderness, juiciness, and duration of chewing for each sample in the mouth. Muscle activity was less for the edentulous group, particularly that of the masseter muscles. The masticatory pattern of complete denture wearers was less adapted to each sample texture than was that of the control group. Both groups perceived differences in texture of the samples. It was concluded that although texture perception is little altered, muscular adaptation to the bolus is reduced in patients with complete dentures.

Entities:  

Mesh:

Year:  2000        PMID: 10768719     DOI: 10.1034/j.1600-0722.2000.90780.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  4 in total

1.  Edentulation alters material properties of cortical bone in the human craniofacial skeleton: functional implications for craniofacial structure in primate evolution.

Authors:  Paul C Dechow; Qian Wang; Jill Peterson
Journal:  Anat Rec (Hoboken)       Date:  2010-04       Impact factor: 2.064

2.  Impact of removable partial denture prosthesis on chewing efficiency.

Authors:  Marion Bessadet; Emmanuel Nicolas; Marine Sochat; Martine Hennequin; Jean-Luc Veyrune
Journal:  J Appl Oral Sci       Date:  2013 Sep-Oct       Impact factor: 2.698

3.  Electromyographic evaluation of mastication and swallowing in elderly individuals with mandibular fixed implant-supported prostheses.

Authors:  Giédre Berretin-Felix; Hugo Nary Filho; Carlos Roberto Padovani; Alceu Sergio Trindade Junior; Wellington Monteiro Machado
Journal:  J Appl Oral Sci       Date:  2008 Mar-Apr       Impact factor: 2.698

4.  ElectromyoFigureic Evaluation of Functional Adaptation of Patients with New Complete Dentures.

Authors:  Kujtim Sh Shala; Linda J Dula; Teuta Pustina-Krasniqi; Teuta Bicaj; Enis F Ahmedi; Zana Lila-Krasniqi; Arlinda Tmava-Dragusha
Journal:  Int J Dent       Date:  2018-03-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.