Literature DB >> 10768024

An Arabic letter distance visual acuity test chart for young children and illiterate adults.

A O Oduntan1, S T Briggs.   

Abstract

This paper describes the design of a kinetic response Arabic letter distance visual acuity test chart for young children and illiterate adults. An Arabic letter ein which has previously been used in the design of Arabic alphabet VA charts was employed. Four different orientations of the letter were constructed on a 5 x 5 unit format and graded according to log MAR principle of acuity scaling using an Apple computer. Inter-letter space in each row was made equal to the width of each letter in the row, and inter-row space was made equal to the height of letters in the next lower row. The chart has 14 acuity rows ranging from 4/40 to 4/2 (6/60 to 6/3) (20/200 to 20/10) (log MAR 1.0 to -0.3) at 4 metres. To establish the validity of the chart, acuity values obtained using the chart were compared with those from an existing Arabic log MAR distance VA chart and the Bailey and Lovie distance VA chart. Test retest reliability of the chart was also examined statistically. Results show that VA values from the new chart were significantly similar with those from which it was compared, and that values from the chart are reliable. The chart will be useful for evaluating vision, especially for young children and illiterate adults.

Entities:  

Mesh:

Year:  1999        PMID: 10768024     DOI: 10.1046/j.1475-1313.1999.00454.x

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  4 in total

1.  Toward developing a standardized Arabic continuous text reading chart.

Authors:  Balsam Alabdulkader; Susan Jennifer Leat
Journal:  J Optom       Date:  2016-05-06

2.  A standardized logarithm of the minimum angle of resolution visual acuity chart in Hindi.

Authors:  Ananth Sailoganathan; Ebi Peter Osuobeni; John Siderov
Journal:  Indian J Ophthalmol       Date:  2018-05       Impact factor: 1.848

3.  A new Gujarati language logMAR visual acuity chart: development and validation.

Authors:  Ananth Sailoganathan; John Siderov; Ebi Osuobeni
Journal:  Indian J Ophthalmol       Date:  2013-10       Impact factor: 1.848

4.  A modified Middle Eastern contrast sensitivity chart.

Authors:  Mohammad Bagher Hadavand; Fatemeh Heidary; Roghayeh Heidary; Reza Gharebaghi
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2014
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.