Literature DB >> 10767075

Magnetic resonance imaging of ultrasound fields: gradient characteristics.

D B Plewes1, S Silver, B Starkoski, C L Walker.   

Abstract

Phase-contrast magnetic resonance imaging (MRI) is used to image particle displacements arising from a 0.515-MHZ focused ultrasound (US) field. The technique used a phase-locked, self-resonant gradient matched to the US frequency in conjunction with a spin-echo sequence to generate phase images of US-induced displacement parallel to the US propagation direction. The gradient design was numerically optimized to provide maximum linearity and magnitude while minimizing gradient inductance. The windings were fabricated of Litz wire to minimize resistive losses and mounted in an oil-cooled imaging chamber. When driven by a resonance power supply, a peak magnetic field gradient of 0.40 T/m was attained with a peak current of 20 amp in a volume of 53 cm(3), achieving stable oscillation at the required US frequency. Clear detection of the nanometer scale particle motions of the US field was achieved and allowed quantitative, noninvasive visualization of the entire US field. While the required gradient slew rate for US detection is beyond that recommended for in vivo application, this imaging method opens new possibilities for in vitro or ex vivo research in the study of the interaction of US with tissue. Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2000        PMID: 10767075     DOI: 10.1002/(sici)1522-2586(200004)11:4<452::aid-jmri14>3.0.co;2-y

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

1.  Harmonic Motion Imaging (HMI) for Tumor Imaging and Treatment Monitoring.

Authors:  Elisa E Konofagou; Caroline Maleke; Jonathan Vappou
Journal:  Curr Med Imaging Rev       Date:  2012

2.  Measurement of the dynamic shear modulus of mouse brain tissue in vivo by magnetic resonance elastography.

Authors:  Stefan M Atay; Christopher D Kroenke; Arash Sabet; Philip V Bayly
Journal:  J Biomech Eng       Date:  2008-04       Impact factor: 2.097

3.  Magnetic resonance microwave absorption imaging: feasibility of signal detection.

Authors:  Bin Xie; John B Weaver; Paul M Meaney; Keith D Paulsen
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

4.  Magnetic resonance shear wave elastography using transient acoustic radiation force excitations and sinusoidal displacement encoding.

Authors:  Lorne W Hofstetter; Henrik Odéen; Bradley D Bolster; Douglas A Christensen; Allison Payne; Dennis L Parker
Journal:  Phys Med Biol       Date:  2021-02-26       Impact factor: 3.609

Review 5.  Acoustic Radiation Force Based Ultrasound Elasticity Imaging for Biomedical Applications.

Authors:  Lulu Wang
Journal:  Sensors (Basel)       Date:  2018-07-12       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.