Literature DB >> 10765868

Aerosol reduction during air polishing.

S K Harrel1, J B Barnes, F Rivera-Hidalgo.   

Abstract

OBJECTIVES: Concern has been expressed about the obvious aerosol cloud that is generated during air polishing of teeth. These concerns have included infection control, potential systemic effects, and environmental surface contamination associated with the particles of sodium bicarbonate powder, water, and patient-generated material. This in vitro study evaluated an aerosol reduction device designed for use during air polishing. METHOD AND MATERIALS: Eight artificial teeth on a Dentoform model were polished with and without the aerosol reduction device. The polishing was performed within a plastic enclosure that had a grid on the sides. The water supply for the air polisher contained a 1% fluorescein solution. The aerosol contamination was determined by counting the number of squares that showed fluorescent spots under an ultraviolet light.
RESULTS: The mean contamination without the aerosol reduction device was 175.59 cm2. The mean contamination with the aerosol reduction device was 4.37 cm2, a greater than 97% reduction in aerosol contamination.
CONCLUSION: The aerosol reduction device significantly decreased the contamination produced during air polishing.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10765868

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  5 in total

Review 1.  Reopening of dental clinics during SARS-CoV-2 pandemic: an evidence-based review of literature for clinical interventions.

Authors:  Seied Omid Keyhan; Hamid Reza Fallahi; Amin Motamedi; Vahid Khoshkam; Paymon Mehryar; Omid Moghaddas; Behzad Cheshmi; Parsa Firoozi; Parisa Yousefi; Behzad Houshmand
Journal:  Maxillofac Plast Reconstr Surg       Date:  2020-08-03

2.  Influence of flow rate and different size of suction cannulas on splatter contamination in dentistry: results of an exploratory study with a high-volume evacuation system.

Authors:  Christian Graetz; Viktor Hülsbeck; Paulina Düffert; Susanne Schorr; Martin Straßburger; Antje Geiken; Christof E Dörfer; Miriam Cyris
Journal:  Clin Oral Investig       Date:  2022-05-10       Impact factor: 3.606

Review 3.  Modifications of emergency dental clinic protocols to combat COVID-19 transmission.

Authors:  Robert Hollinshead Long; Tyrous David Ward; Michael Edward Pruett; John Finklea Coleman; Marc Charles Plaisance
Journal:  Spec Care Dentist       Date:  2020-05-24

4.  Quantitative measurements of aerosols from air-polishing and ultrasonic devices: (How) can we protect ourselves?

Authors:  Manuela Kaufmann; Alex Solderer; Andrea Gubler; Florian J Wegehaupt; Thomas Attin; Patrick R Schmidlin
Journal:  PLoS One       Date:  2020-12-15       Impact factor: 3.240

Review 5.  Aerosols and splatter in dentistry: a brief review of the literature and infection control implications.

Authors:  Stephen K Harrel; John Molinari
Journal:  J Am Dent Assoc       Date:  2004-04       Impact factor: 3.634

  5 in total