Accurate assessment of in situ isometric contractile properties of hindlimb plantar and dorsal flexor muscle complex of intact mice.

M Gorselink1, M R Drost, J de Louw, P J Willems, N Rosielle, J D Janssen, G J van der Vusse.   

Abstract

An isometric torque sensor for measuring in situ contractions of plantar or dorsal flexors of intact mouse hindlimb has been developed and evaluated. With this device, muscle torque can be accurately measured within the range of -14 mN.m to +14 mN.m. Special attention was paid to fixation of the mouse hindlimb to the measurement device. Halothane-anaesthetized Swiss wild-type mice were positioned on the thermostatic measurement platform, and fixated with a hip and foot fixation system. The novel fixation unit was evaluated by measuring knee and ankle displacements during a contraction. A mathematical muscle model was used to quantify the effects of these displacements on the contractile parameters. Measured ankle and knee displacement, due to non-absolute fixation. resulted in a calculated muscle fibre shortening of 2.5%. Simulations of a contraction with this degree of fibre shortening, using the mathematical muscle model, showed only minor effects on maximal torque generation and the temporal parameters (half-relaxation time and 10-50% rise time). Furthermore, we showed that muscle torque in our set-up is hardly affected by eccentricity between ankle and measurement axis. Measured tetanic muscle torques of intact dorsal and plantar flexors were 3.2+/-0.4 mN.m and 11.8+/-1.6 mN.m, respectively. The half-relaxation time of plantar flexors was significantly higher than that of dorsal flexors (12.9+/-2.7 ms versus 8.8+/-1.2 ms), whereas the 10-50% rise time was longer in plantar (14.9+/-0.6 ms) than in dorsal (11.8+/-2.0 ms) flexors.

Entities:  

Mesh:

Year:  2000        PMID: 10764228     DOI: 10.1007/s004249900208

Source DB:  PubMed          Journal:  Pflugers Arch        ISSN: 0031-6768            Impact factor:   3.657


  2 in total

1.  An MR-compatible device for the in situ assessment of isometric contractile performance of mouse hind-limb ankle flexors.

Authors:  Maarten R Drost; Anneriet M Heemskerk; Gustav J Strijkers; Erwin C Dekkers; Gerrit van Kranenburg; Klaas Nicolay
Journal:  Pflugers Arch       Date:  2003-10-07       Impact factor: 3.657

2.  Molecular, physiological, and motor performance defects in DMSXL mice carrying >1,000 CTG repeats from the human DM1 locus.

Authors:  Aline Huguet; Fadia Medja; Annie Nicole; Alban Vignaud; Céline Guiraud-Dogan; Arnaud Ferry; Valérie Decostre; Jean-Yves Hogrel; Friedrich Metzger; Andreas Hoeflich; Martin Baraibar; Mário Gomes-Pereira; Jack Puymirat; Guillaume Bassez; Denis Furling; Arnold Munnich; Geneviève Gourdon
Journal:  PLoS Genet       Date:  2012-11-29       Impact factor: 5.917

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.