| Literature DB >> 10763263 |
.
Abstract
In process analytical applications it is not always possible to keep the measurement conditions constant. However, fluctuations in external variables such as temperature can have a strong influence on measurement results. For example, nonlinear temperature effects on near-infrared (NIR) spectra may lead to a strongly biased prediction result from multivariate calibration models such as PLS. A new method, called Continuous Piecewise Direct Standardization (CPDS) has been developed for the correction of such external influences. It represents a generalization of the discrete PDS calibration transfer method and is able to adjust for continuous nonlinear influences such as the temperature effects on spectra. It was applied to shortwave NIR spectra of ethanol/water/2-propanol mixtures measured at different temperatures in the range 30-70 degrees C. The method was able to remove, almost completely, the temperature effects on the spectra, and prediction of the mole fractions of the chemical components was close to the results obtained at constant temperature.Entities:
Year: 2000 PMID: 10763263 DOI: 10.1021/ac9906835
Source DB: PubMed Journal: Anal Chem ISSN: 0003-2700 Impact factor: 6.986