In vitro characteristics of red blood cell concentrates prepared from under- and overcollected units of whole blood and from a paediatric blood bag system.

V Weisbach1, I Hunold, R Zimmermann, N Lutter, H Parsch, J Zingsem, A Glaser, R Eckstein.   

Abstract

The problem of how to deal with red blood cell concentrates (RBCs) prepared from under- or overcollected units of whole blood (WB) and how to collect blood from underweight persons arises in the context of autologous predeposit. To determine the quality of RBCs stored in PAGGS-M additive solution prepared from under- and overcollected units of whole blood and of PAGGS-M RBCs prepared from a paediatric 250-mL top outlet blood bag system we measured blood picture, haemolysis, K+, pH, ATP and 2,3-DPG on days 0, 10, 20, 30, 40 and 49 of storage. The volume of WB collected ranged from 150 to 600 mL in 50-mL increments (4 units per volume). Haemolysis was under 0.8% on day 49 in all RBCs prepared from WB donations between 200 mL and 600 mL. However, the day 49 haemolysis level of standard RBCs prepared from 450 mL of WB (0.15 +/- 0.03%) was reached earlier in RBCs from under- and overcollected units of whole blood. 2,3-DPG levels decreased rapidly between days 10 and 20 in all RBCs studied. RBCs from 450-mL donations showed acceptable ATP maintenance after 49 days (70.4% of day 0 value), while all other RBC ATP levels were below 50% of the day 0 level on day 49. In vitro quality data of RBCs prepared from a 250-mL donation in the paediatric blood bag system after storage for about 25 days were comparable to those after 49 days of storage of standard RBCs. Our results suggest that it is feasible to transfuse PAGGS-M RBCs prepared from under- as well as overcollected units of WB in the autologous setting. However, we strongly recommend shortening the storage period of such RBCs to maintain the quality level of standard RBCs.

Entities:  

Mesh:

Year:  2000        PMID: 10760200     DOI: 10.1046/j.1365-3148.2000.00228.x

Source DB:  PubMed          Journal:  Transfus Med        ISSN: 0958-7578            Impact factor:   2.019


  3 in total

1.  Prospective, Paired Crossover Comparison of the in vitro Quality of Red Blood Cells Collected by the Automate for Blood Collection Device or by a Conventional Method.

Authors:  Stefano Fontana; Tina Weingand; Andreas Maier; Behrouz Mansouri Taleghani
Journal:  Transfus Med Hemother       Date:  2009-07-21       Impact factor: 3.747

2.  Erythrocyte concentrates recovered from under-collected whole blood: experimental and clinical results.

Authors:  Wen-Biao Liang; Ming-Hua Guo; En-Yong Fan; Jing-Jing Zhang; Min-Hui Wu; Yan-Chun Liu; Li Cai; Zheng-Gang Li; Bing Huang; Peng Wei; Jun Sun; Yi Zhu
Journal:  PLoS One       Date:  2015-02-23       Impact factor: 3.240

3.  Quality of red blood cells isolated from umbilical cord blood stored at room temperature.

Authors:  Mariia Zhurova; John Akabutu; Jason Acker
Journal:  J Blood Transfus       Date:  2011-12-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.