Literature DB >> 10758920

Clinical and angiographic outcome after coronary arterial stenting with the carbostent.

D Antoniucci1, A Bartorelli, R Valenti, P Montorsi, G M Santoro, F Fabbiocchi, L Bolognese, A Loaldi, M Trapani, D Trabattoni, G Moschi, S Galli.   

Abstract

The Carbostent is a new balloon-expandable, stainless steel, tubular stent with innovative multicellular design and unique turbastratic carbon coating (Carbofilm). This open nonrandomized 2-center study assesses the immediate and long-term clinical and angiographic outcomes after Carbostent implantation in patients with native coronary artery disease. The Carbostent was implanted in 112 patients with 132 de novo lesions. Most patients (55%) had unstable angina, and 38% of lesions were type B2-C. The mean lesion length was 12.5 +/- 7.0 mm, and 29% of lesions were > 15 mm in length. No stent deployment failure occurred, as well as acute or sub-acute stent thrombosis. The 6-month event-free survival was 84 +/- 4%. One patient with a stented right coronary artery and no restenosis at the angiographic follow-up died after 6 months of fatal infarction due to abrupt closure of a nontarget vessel. In-hospital non-Q-wave myocardial infarction occurred in 1 patient, and 11 patients had repeat target lesion revascularization (target lesion revascularization rate 10%). The 6-month angiographic follow-up was obtained in 108 patients (96%) (127 lesions). Angiographic restenosis rate was 11%. The loss index was 0.29 +/- 0.28. The results of this study indicate a potential benefit of Carbostent for the prevention of stent thrombosis and restenosis in these relatively high-risk patients. A larger trial is being planned to confirm these promising results.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10758920     DOI: 10.1016/s0002-9149(99)00874-7

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

Review 1.  Coronary stents: in these days of climate change should all stents wear coats?

Authors:  R Lowe; I B A Menown; G Nogareda; I M Penn
Journal:  Heart       Date:  2005-06       Impact factor: 5.994

2.  Tacrolimus-eluting carbon-coated stents versus sirolimus-eluting stents for prevention of symptom-driven clinical end points.

Authors:  J M Siller-Matula; I Tentzeris; B Vogel; S Schacherl; R Jarai; A Geppert; G Unger; K Huber
Journal:  Clin Res Cardiol       Date:  2010-04-20       Impact factor: 5.460

3.  Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model.

Authors:  J H Kim; J H Shin; D H Shin; M-W Moon; K Park; T-H Kim; K M Shin; Y H Won; D K Han; K-R Lee
Journal:  Br J Radiol       Date:  2011-03       Impact factor: 3.039

Review 4.  Surface engineering and the application of laser-based processes to stents - A review of the latest development.

Authors:  J Dong; M Pacella; Y Liu; L Zhao
Journal:  Bioact Mater       Date:  2021-08-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.