Right and left ventricular volume measurements in an animal heart model in vitro: first experiences with cardiac MRI at 1.0 T.

J A Koch1, L W Poll, E Godehardt, B Korbmacher, U Mödder.   

Abstract

The aim of this study was to determine the accuracy in quantifying right and left ventricular volumes using a 1.0-T system and commercially available, standard equipment. For exact comparison of MRI measurements and real volumes we used an animal heart model ex vivo. Eight pig hearts were explanted and prepared by removal of the atria. Aorta and pulmonary truncus were cannulated. Definable volumes were injected into the ventricles. Magnetic resonance imaging was performed at 1.0 T (Gyroscan T10 NT, Philips, Eindhoven, The Netherlands); sequence: fast field echo-echo planar (multishot EPI); body coil; MR software: Cardiac Application Package (Philips). Statistical analysis correlated the real volumes and MR measurements separately for both ventricles and two investigators (SAS, ANOVA). For both ventricles and both investigators the correlation between real volumes and MR measurements was greater than 0.99. There was no significant systematic false estimation for both ventricles. Magnetic resonance imaging at 1.0 T using standard hardware and software equipment enables the quantification of right and left ventricular volumes with high approximation to the real volumes in vitro. There is a clear restriction in translating these data into a clinical application because under experimental conditions no motion-induced artifacts existed.

Entities:  

Mesh:

Year:  2000        PMID: 10756995     DOI: 10.1007/s003300050075

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  8 in total

1.  Measurement of left ventricular volume after anterior myocardial infarction: comparison of magnetic resonance imaging, echo and radionuclide ventriculography.

Authors:  S Prasad; D Pennell
Journal:  Int J Cardiovasc Imaging       Date:  2002-10       Impact factor: 2.357

2.  Is MRI the preferred method for evaluating right ventricular size and function in patients with congenital heart disease?: MRI is the preferred method for evaluating right ventricular size and function in patients with congenital heart disease.

Authors:  Tal Geva
Journal:  Circ Cardiovasc Imaging       Date:  2014-01       Impact factor: 7.792

3.  Assessment of the precision and reproducibility of ventricular volume, function, and mass measurements with ferumoxytol-enhanced 4D flow MRI.

Authors:  Kate Hanneman; Aya Kino; Joseph Y Cheng; Marcus T Alley; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2016-02-12       Impact factor: 4.813

Review 4.  Society for Cardiovascular Magnetic Resonance/European Society of Cardiovascular Imaging/American Society of Echocardiography/Society for Pediatric Radiology/North American Society for Cardiovascular Imaging Guidelines for the Use of Cardiac Magnetic Resonance in Pediatric Congenital and Acquired Heart Disease: Endorsed by The American Heart Association.

Authors:  Mark A Fogel; Shaftkat Anwar; Craig Broberg; Lorna Browne; Taylor Chung; Tiffanie Johnson; Vivek Muthurangu; Michael Taylor; Emanuela Valsangiacomo-Buechel; Carolyn Wilhelm
Journal:  Circ Cardiovasc Imaging       Date:  2022-06-21       Impact factor: 8.589

Review 5.  Society for Cardiovascular Magnetic Resonance/European Society of Cardiovascular Imaging/American Society of Echocardiography/Society for Pediatric Radiology/North American Society for Cardiovascular Imaging Guidelines for the use of cardiovascular magnetic resonance in pediatric congenital and acquired heart disease : Endorsed by The American Heart Association.

Authors:  Mark A Fogel; Shaftkat Anwar; Craig Broberg; Lorna Browne; Taylor Chung; Tiffanie Johnson; Vivek Muthurangu; Michael Taylor; Emanuela Valsangiacomo-Buechel; Carolyn Wilhelm
Journal:  J Cardiovasc Magn Reson       Date:  2022-06-21       Impact factor: 6.903

Review 6.  The role of cardiovascular magnetic resonance in the assessment of severe aortic stenosis and in post-procedural evaluation following transcatheter aortic valve implantation and surgical aortic valve replacement.

Authors:  Tarique Al Musa; Sven Plein; John P Greenwood
Journal:  Quant Imaging Med Surg       Date:  2016-06

Review 7.  Heart valve disease: investigation by cardiovascular magnetic resonance.

Authors:  Saul G Myerson
Journal:  J Cardiovasc Magn Reson       Date:  2012-01-19       Impact factor: 5.364

Review 8.  Advances in clinical applications of cardiovascular magnetic resonance imaging.

Authors:  W P Bandettini; A E Arai
Journal:  Heart       Date:  2008-01-20       Impact factor: 5.994

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.