Literature DB >> 10750915

Comparison of a new screw-tipped intraosseous needle versus a standard bone marrow aspiration needle for infusion.

H Jun1, A Z Haruyama, K S Chang, L G Yamamoto.   

Abstract

The purpose of this study is to compare the speed and ease of establishing intraosseous infusion using a standard bone marrow needle (SBMN; $8) and a new screw-tipped intraosseous needle (Sur-Fast; $42). The study is an experimental design. A total of 42 medical students, without prior IO experience, were recruited as study subjects. Subjects were randomized to perform the IO procedures in one of two models: (1) turkey femur or (2) pork ribs. Each subject performed an initial trial using both IO needles without practice (inexperienced) and a second trial using both IO needles after practice (experienced attempt), such that in total, each subject completed four attempts (two with each needle type). IO placement times were measured, and placement difficulty scores were measured using a 10 cm visual analog scale (VAS). The averaged elapsed time to successful IO completion was significantly shorter for the SBMN in the initial "inexperienced" attempt (33 versus 54 seconds, P = .019), but there was no significant difference in the postpractice "experienced" attempt. VAS difficulty scores were lower (easier) for the SBMN for both inexperienced and experienced trials. Success rates were significantly higher for the Sur-Fast needle during the experienced attempt (95% versus 79%, P < .05), but there was no significant difference in success rates during the inexperienced attempt. The Sur-Fast screw-tipped intraosseous needle does not show superiority over the SBMN in this intraosseous model, therefore its higher cost is difficult to justify based on this study.

Entities:  

Mesh:

Year:  2000        PMID: 10750915     DOI: 10.1016/s0735-6757(00)90003-2

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  6 in total

Review 1.  A systematic review of the methodological quality and outcomes of RCTs to teach medical undergraduates surgical and emergency procedures.

Authors:  Roger E Thomas; Rodney Crutcher; Diane Lorenzetti
Journal:  Can J Surg       Date:  2007-08       Impact factor: 2.089

2.  [Vascular access in emergency paediatric anaesthesia].

Authors:  E-M Jordi Ritz; T O Erb; F J Frei
Journal:  Anaesthesist       Date:  2005-01       Impact factor: 1.041

3.  Intraosseous vascular access in adults using the EZ-IO in an emergency department.

Authors:  Adeline Su-Yin Ngo; Jen Jen Oh; Yuming Chen; David Yong; Marcus Eng Hock Ong
Journal:  Int J Emerg Med       Date:  2009-08-11

4.  [Intraosseous infusion for adults].

Authors:  B A Leidel; C Kirchhoff
Journal:  Chirurg       Date:  2008-04       Impact factor: 0.955

5.  Effectiveness of a Drill-assisted Intraosseous Catheter versus Manual Intraosseous Catheter by Resident Physicians in a Swine Model.

Authors:  John W Hafner; Adam Bryant; Felix Huang; Keir Swisher
Journal:  West J Emerg Med       Date:  2013-11

6.  Complication with intraosseous access: scandinavian users' experience.

Authors:  Peter Hallas; Mikkel Brabrand; Lars Folkestad
Journal:  West J Emerg Med       Date:  2013-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.