Literature DB >> 10750139

Prevention of the initiation of atrial fibrillation: mechanism and efficacy of different atrial pacing modes.

W C Yu1, C F Tsai, M H Hsieh, C C Chen, C T Tai, Y A Ding, M S Chang, S A Chen.   

Abstract

Several atrial pacing modes have been reported to be effective in the prevention of atrial fibrillation (AF); they included biatrial pacing, dual site right atrial pacing, Bachmann's bundle (BB) pacing, and coronary sinus pacing. However, the relative efficacy and electrophysiological mechanisms of these pacing modes in the prevention of AF are not clear. In 15 patients (age 54 +/- 14 years) with paroxysmal AF, P wave duration, effective refractory period, and atrial conduction time were determined with six different atrial drive pacings, that were right atrial appendage (RAA), BB, right posterior interatrial septum (RPS), distal coronary sinus (DCS), RAA plus RPS simultaneously (DSA), and RAA plus DCS simultaneously (BiA). All these patients consistently had AF induced with early RAA extrastimulation coupling to RAA drive pacing. No patient had AF induced with RAA extrastimulation coupled to BB, RPS, or DCS drive pacing, but seven and eight patients had AF induced with RAA extrastimulation coupled to DSA and BiA drive pacing, respectively. The P wave duration was longest during RAA pacing, and became shorter during other atrial pacing modes. Analysis of electrophysiological change showed that early RAA extrastimulation coupled to RAA drive pacing caused the longest atrial conduction delay among these atrial pacing modes; BB, RPS, and DCS drive pacing caused a greater reduction of this conduction delay than DSA and BiA drive pacing. In addition, the effective refractory periods of RAA determined with BB, RPS, and DCS drive pacing were similar and longer than that determined with DSA and BiA drive pacing. In patients with paroxysmal AF, this arrhythmia was readily induced with RAA extrastimuli coupled to RAA drive pacing. BB, RPS, and DCS pacing were similar and more effective than DSA and BiA pacing in preventing AF.

Entities:  

Mesh:

Year:  2000        PMID: 10750139     DOI: 10.1111/j.1540-8159.2000.tb06764.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  10 in total

1.  Optimal positioning of temporary epicardial atrial pacing leads after cardiac surgery.

Authors:  I Kashima; H Shin; R Yozu; S Kawada
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2001-05

2.  [The role of cardiac pacing in atrial arrhythmia prevention].

Authors:  G Fröhlig
Journal:  Z Kardiol       Date:  2005

3.  Interatrial septum versus right atrial appendage pacing for prevention of atrial fibrillation : A meta-analysis of randomized controlled trials.

Authors:  L Zhang; H Jiang; W Wang; J Bai; Y Liang; Y Su; J Ge
Journal:  Herz       Date:  2017-07-28       Impact factor: 1.443

4.  Comparison of the Influence of Right Atrial Septal Pacing and Appendage Pacing on an Atrial Function and Atrial Fibrillation in the Clinical Situation.

Authors:  Mariko Tanaka; Su Kanae; Maki Maki-Oi; Yasuyo Motohashi; Kousuke Takahashi; Ko Euihong; Koji Hanazawa; Mamoru Toyofuku; Masahiko Kitada; Yousuke Yuzuki; Takashi Tamura
Journal:  J Atr Fibrillation       Date:  2016-06-30

5.  Prevention of short term reversible chronic atrial fibrillation by permanent pacing at the triangle of Koch.

Authors:  L Padeletti; M C Porciani; A Michelucci; A Colella; A Costoli; C Ciapetti; P Pieragnoli; N Musilli; G F Gensini
Journal:  J Interv Card Electrophysiol       Date:  2000-12       Impact factor: 1.900

6.  Merits and limitations of the mode switching rate stabilization pacing algorithms in the implantable cardioverter defibrillator.

Authors:  B Dijkman; H J Wellens
Journal:  J Interv Card Electrophysiol       Date:  2001-09       Impact factor: 1.900

Review 7.  Atrial fibrillation: profit from cardiac pacing?

Authors:  A Yang; B Lüderitz; T Lewalter
Journal:  Z Kardiol       Date:  2005-03

8.  Bachmann bundle pacing reduces atrial electromechanical delay in type 1 myotonic dystrophy patients.

Authors:  Vincenzo Russo; Anna Rago; Andrea Antonio Papa; Giulia Arena; Luisa Politano; Gerardo Nigro
Journal:  J Interv Card Electrophysiol       Date:  2018-02-27       Impact factor: 1.900

Review 9.  [Bachmann bundle pacing].

Authors:  C W Israel; T Burmistrava; C Berger
Journal:  Herz       Date:  2018-11       Impact factor: 1.443

Review 10.  New approaches to atrial fibrillation management: a critical review of a rapidly evolving field.

Authors:  Stanley Nattel; Paul Khairy; Denis Roy; Bernard Thibault; Peter Guerra; Mario Talajic; Marc Dubuc
Journal:  Drugs       Date:  2002       Impact factor: 9.546

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.