Literature DB >> 10746452

CxGELSIX: a novel preparation of type VI collagen with possible use as a biomaterial.

M Lekskul1, R Burrows, C L Kublin, C Cintron.   

Abstract

PURPOSE: This study was initiated to evaluate tissue acceptance and stability of a novel type VI collagen preparation (CxGelsix) as a biomaterial in the rabbit corneal stroma. We hypothesized that CxGelsix, embedded intrastromally, does not have any adverse affect on surrounding corneal tissues, and remains intact in the presence of an acute inflammatory reaction during corneal wound healing.
METHODS: Type VI collagen was extracted and purified from rabbit corneal stroma under nondenaturing conditions. This preparation, Gelsix, was concentrated and cross-linked with polyethylene glycol to produce a transparent film (CxGelsix). Discs of CxGelsix, 4.0-mm diameter, 9- to 35-microm thick were implanted intrastromally and clinically examined periodically for 4 months. In another experiment, implantation of CxGelsix, 2.0-mm-diameter, was followed by corneal wounding adjacent to the implant and examined clinically for 30 weeks. At the end of these periods, the tissues from these experiments were processed for light and transmission electron microscopy.
RESULTS: An intralamellar 4.0-mm-diameter disc of CxGelsix does not alter the structure of corneal epithelium above the implant, suggesting normal transport of nutrients through CxGelsix. Moreover, no structural abnormalities were seen in the rest of the cornea, and the cornea remains transparent. Although the cornea accepts the presence of CxGelsix disc as judged by clinical criteria, gradual degradation of the implant is seen ultrastructurally. CxGelsix is remarkably stable despite its exposure to endogenous enzymes during inflammation and wound healing. Partial degradation of the implant occurs only after many months, and it is gradually replaced with bundles of fine collagen fibrils reminiscent of normal cornea.
CONCLUSION: The results of this study suggest that CxGelsix is potentially useful as a biomaterial.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10746452     DOI: 10.1097/00003226-200003000-00013

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  2 in total

1.  Evaluation of umbilical cord serum therapy for persistent corneal epithelial defects.

Authors:  R B Vajpayee; N Mukerji; R Tandon; N Sharma; R M Pandey; N R Biswas; N Malhotra; S A Melki
Journal:  Br J Ophthalmol       Date:  2003-11       Impact factor: 4.638

2.  In vivo biocompatibility of two PEG/PAA interpenetrating polymer networks as corneal inlays following deep stromal pocket implantation.

Authors:  Xiao Wei Tan; Laura Hartman; Kim Peng Tan; Rebekah Poh; David Myung; Luo Luo Zheng; Dale Waters; Jaan Noolandi; Roger W Beuerman; Curtis W Frank; Christopher N Ta; Donald T H Tan; Jodhbir S Mehta
Journal:  J Mater Sci Mater Med       Date:  2013-01-26       Impact factor: 3.896

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.